Datasheet
Etherea with enhanced Econavi sensor and new Nanoe-G air-purifying system: outstanding
efficiency, comfort and healthy air combined with state-of-the-art design.
Econavi features an in-built human activity sensor and a new sunlight detection technology to adjust output
thereby giving you the best comfort at anytime whilst saving energy. Econavi not only optimizes air flow
orientation and volume according to human presence, it also reduces cooling power automatically by no/less
sunshine. With econavi, you will achieve up to 38% energy savings whilst increasing your comfort.
Furthermore, the Nanoe-G revolutionary air-purifying system utilises nano technology fine particles to remove
and deactivate 99% of both airborne and adhesive micro-organisms like bacteria, viruses and mould.
WALL MOUNTED ETHEREA
INVERTER+
SILVER PLATED / WHITE
INTERNET CONTROL READY: Optional. MILD DRY: Maintains a Relative Humidity up to 10% higher than cooling operation. Ideal when sleeping with the air conditioner on.
A class
energy saving
Easy
control
by BMS
CONNECTIVITY
5 year
compressor
warranty
Up to 38%
energy savings
(cooling)
Air purifier
99%
removal
bacteria · virus · mold
Perfect
humidity
control
MILD DRY
Improved
comfort
AUTOCOMFORT
Internet
Control
Ready
INTERNET CONTROL
OPTIONAL
Kit Silver Plated KIT-XE18-PKE KIT-XE21-PKE — —
Kit Silver Plated / with Smartphone Control KIT-XE18-PKE-WIFI KIT-XE21-PKE-WIFI — —
Kit White KIT-E18-PKE KIT-E21-PKE KIT-E24-PKE KIT-E28-PKE
Kit White / with Smartphone Control KIT-E18-PKE-WIFI KIT-E21-PKE-WIFI KIT-E24-PKE-WIFI KIT-E28-PKE-WIFI
Indoor Silver plated CS-XE18PKEW CS-XE21PKEW — —
Indoor White CS-E18PKEW CS-E21PKEW CS-E24PKEW CS-E28PKES
Outdoor CU-E18PKE CU-E21PKE CU-E24PKE CU-E28PKE
Cooling capacity Nominal (Min - Max) kW 5.00 (0.98-6.00) 6.30 (0.98-7.10) 6.80 (0.98-8.10) 7.65 (0.98-8.60)
Nominal (Min - Max) kCal/h 4,300 (840-5,160) 5,420 (840-6,110) 5,850 (840-6,970) 6,580 (840-7,400)
EER
1)
Nominal (Min - Max) Energy Saving
3,47 (3.50-3,02)
A
2.89 (3.50-2.84)
C
3.27 (2.58-3.06)
A
3.04 (2.58-2.95)
B
SEER Nominal Energy Saving
6.9
A++
6.5
A++
6.1
A++
6.0
A+
Pdesign (cooling) 5.0 6.3 6.8 7.7
Power input Cooling Nominal (Min - Max) kW 1.44 (0.28-1.99) 2.18 (0.28-2.50) 2.08 (0.38-2.65) 2.52 (0.38-2.92)
Annual Energy Consumption (Cooling)
2)
kWh 254 339 390 449
Heating capacity Nominal (Min - Max) kW 5.80 (0.98-8.00) 7.20 (0.98-8.50) 8.60 (0.98-9.90) 9.60 (0.98-11.00)
Heating capacity at -7 °C Nominal kW 4,990 (840-6,880) 6,190 (840-7,310) 7,400 (840-8,510) 8,260 (840-9,460)
COP
1)
Nominal (Min - Max) Energy Saving 3.82 (2.88-3.11) A 3.44 (2.88-3.11) B 3.31 (2.18-3.16) C 2.94 (2.18-2.97) D
SCOP Nominal Energy Saving
4.2
A+
4.0
A+
3.8
A
3.8
A
Pdesign at -10 °C kW 4.4 4.6 5.5 6.0
Power input Heating Nominal (Min - Max) kW 1.520 (0.340-2.570) 2.09 (0.34-2.73) 2.60 (0.45-3.13) 3.26 (0.45-3.70)
Annual Energy Consumption (Heating)
2)
kWh 1467 1610 2026 2333
Indoor Unit
Power source V 230 230 230 230
Recommended Fuse A
Recommended power cable section mm²
Connection indoor / outdoor mm² 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5
Current (Nominal) Cooling / Heating A 6.4 / 6.8 9.7 / 9.4 9.5 / 11.8 11.5 / 14.6
Max. current A 11.3 11.9 13.8 15.5
Air Volume Cooling / Heating m³/h 1074 / 1158 1,034 / 1,200 1,188 / 1,272 1,266 / 1,314
Moisture removal volume l/h 2.8 3.5 3.9 4.5
Sound pressure Level
2)
Cooling (Hi / Lo / S-Lo) dB(A) 44 / 37 / 34 45 / 37 / 34 47 / 38 / 35 49 / 38 / 35
Heating (Hi / Lo / S-Lo) dB(A) 44 / 37 / 34 45 / 37 / 34 47 / 38 / 35 48 / 38 / 35
Sound power Level Cooling / Heating (Hi) dB 60 / 60 61 / 61 63 / 63 65 / 64
Dimensions
3)
H x W x D mm 295 x 1,070 x 255 295 x 1,070 x 255 295 x 1,070 x 255 295 x 1,070 x 255
Net weight Kg 13 13 13 13
Air purifier filter Nanoe-G Nanoe-G Nanoe-G Nanoe-G
Outdoor Unit
Air Volume Cooling / Heating m³/h 2,352 / 2,274 2,502 / 2,424 3,012 / 3,012 3,270 / 3,270
Sound pressure Level
2)
Cooling / Heating (Hi) dB(A) 47 / 47 48 / 49 52 / 52 53 / 53
Sound power Level Cooling / Heating (Hi) dB 61 / 61 62 / 63 66 / 66 67 / 67
Dimensions
3)
H x W x D mm 695 x 875 x 320 695 x 875 x 320 795 x 875 x 320 795 x 875 x 320
Net weight Kg 46 47 67 67
Piping connections Liquid pipe / Gas pipe inch (mm) 1/4" (6.35) / 1/2" (12.70) 1/4" (6.35) / 1/2" (12.70) 1/4" (6.35) / 5/8" (15.88) 1/4" (6.35) / 5/8" (15.88)
Refrigerant Loading R410A (GWP value) Kg 1.24 1.32 1.80 1.80
Elevation difference (in/out)
4)
Max m 15 15 20 20
Piping length Min / Max m 3-20 3-20 3-30 3-30
Piping length without
refrigerant increase
Max m 7.5 7.5 10 10
Additional gas g/m 20 20 30 30
Operating range Cooling Min / Max °C -10 / +43 -10 / +43 -10 / +43 -10 / +43
Heating Min / Max °C -15 / +24 -15 / +24 -15 / +24 -15 / +24
Rating Conditions: Cooling Indoor 27 °C DB / 19 °C WB. Cooling Outdoor 35 °C DB / 24 °C WB. Heating Indoor 20 °C DB. Cooling Outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb)
Connectivity restriction: JKE units are not compatible with PKE units.
1) EER and COP classification is at 230 V in accordance with EU directive 2002/31/EC. 2) The Sound pressure level of the units shows the value measured of a position 1 meter in front of the main body and 0,8 m below the unit. The sound pressure is measured in
accordance with Eurovent 6/C/006-97 specification. 3) Add 70 mm for piping port. 4) When installing the outdoor unit at a higher position than the indoor unit.
Specifications subject to change without notice.
Awarded with the prestigious
IF Design Award 2013
36