Brochure

31
Concealed Duct Air Conditioners & Heat Pumps
Ceiling Suspended Air Conditioners
& Heat Pumps
** This is maximum elevation difference when the indoor unit is located above the outdoor unit. (Refer to the table on the back of the catalog for more detail.)
Outline diagram with medium or
high-performance filter field installed.
Built-In Drain
Pump
Installation Example
Concealed Duct
Air Conditioners
Heat Pumps
Model No. 26PSF1U6 36PSF1U6 26PEF1U6 36PEF1U6
Unit Model No.
Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit
S-26PF1U6 U-26PS1U6 S-26PF1U6 U-36PS1U6 S-26PF1U6 U-26PE1U6 S-36PF1U6 U-36PE1U6
Performance & Electrical Ratings
Capacity Cooling Btu/h 24,000 (9,500 ~ 24,000) 31,200 (9,500 ~ 31,200) 24,000 (9,500 ~ 24,000) 31,200 (9,500 ~ 31,200)
Heating Btu/h --- --- 28,600 (8,000 ~ 28,600) 36,200 (8,000 ~ 36,200)
Moisture Removal High Pints/H 7.7 10.0 7.7 10.0
Dry Air Flow
Hi / Med / Low
CFM 670 / 530 / 460 1,060 / 920 / 750 670 / 530 / 460 1,060 / 920 / 750
SEER Cooling 14.0 13.9 14.0 13.9
EER Cooling 9.1 7.8 9.1 7.8
HSPF Heating
--- ---
9.0 8.5
Power Supply V, Phase, Hz 230 / 208, 1Ph, 60Hz 230 / 208, 1Ph, 60Hz 230 / 208, 1Ph, 60Hz 230 / 208, 1Ph, 60Hz
Running Amps Cooling A 13.6 / 15.0 18.6 / 20.6 13.6 / 15.0 18.6 / 20.6
Heating A
--- ---
12.5 / 13.8 15.9 / 17.6
Power Input Cooling W 2,600 / 2,600 3,920 / 3,920 2,600 / 2,600 3,920 / 3,920
Heating W --- --- 2,400 / 2,400 3,340 / 3,340
External Static Pressure in. WC 0.20 0.24 0.20 0.24
Fuse or Circuit Breaker Capacity A 15 30 15 35 15 30 15 35
Features
Controls Microprocessor Microprocessor Microprocessor Microprocessor
Low Ambient Control Built-in 0˚F Built-in 0˚F Built-in 0˚F Built-in 0˚F
Wireless Remote Controller (optional) CZ-RWSU2U, CZ-RWSC1U CZ-RWSU2U, CZ-RWSC1U CZ-RWSU2U, CZ-RWSC1U CZ-RWSU2U, CZ-RWSC1U
Wired Remote Controller (included) CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2
Fan Speeds 3 and Automatic Control / Variable 3 and Automatic Control / Variable 3 and Automatic Control / Variable 3 and Automatic Control / Variable
Timer 7 Days/6 Events 7 Days/6 Events 7 Days/6 Events 7 Days/6 Events
Air Deflection Horizontal --- --- --- ---
Vertical --- --- --- ---
Air Filter --- --- --- ---
Refrigerant control Electric Expansion Valve Electric Expansion Valve Electric Expansion Valve Electric Expansion Valve
Operation Sound In
(Hi / Me / Lo)
dB-A 34 / 30 / 27 38 / 33 / 31 34 / 30 / 27 38 / 33 / 31
Outdoor(Hi) dB-A 49 52 49 52
Refrigerant Piping Type Flare Flare Flare Flare
Discharge inches 3/8” 3/8” 3/8” 3/8”
Suction inches 5/8” 5/8” 5/8” 5/8”
Refrigerant Pipe Length Ft. Max. 165 Max. 165 Max. 165 Max. 165
Elevation Difference
** Outdoor Above Ft. Max. 100 Max. 100 Max. 100 Max. 100
Outdoor Below Ft. Max. 50 Max. 50 Max. 50 Max. 50
Dimensions & Weight
Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit
Height inches 12-7/32” 30-23/32” 12-7/32” 30-23/32” 12-7/32” 30-23/32” 12-7/32” 30-23/32”
Width inches 39-3/8” 37” 58-9/32” 37” 39-3/8” 37” 58-9/32” 37”
Depth inches 24-13/16” 13-3/8” 24-13/16” 13-3/8” 24-13/16” 13-3/8” 24-13/16” 13-3/8”
Net Weight Lbs. 71.0 128.0 104.0 143.0 71.0 128.0 104.0 143.0
Outdoor Unit
U-26PS1U6
U-26PE1U6
Outdoor Unit
U-36PS1U6
U-36PE1U6
Indoor Unit
S-36PF1U6
Supplies are 8” dia
The picture shows the standard ducting system, where air is taken in from the back
of the unit. This system
is useful for places
which need extensive
air conditioning,
including conference
halls, showrooms,
and restaurants.
Drain pump is built into
the unit to raise the
condensate up 20 inches
from the drain pump dis-
charge.
Wired
Remote Controller
(CZ-RTC2)
(Included)
Wired
Remote Controller
(CZ-RTC2)
(Included)
26PSF1U6 36PSF1U626PEF1U6 36PEF1U6
Indoor Unit
S-26PF1U6
Supplies are 8” dia
(optional)
(heat pump only) (heat pump only)
(optional)
(Field Supplied)
(optional)
(heat pump only) (heat pump only)
(optional)
(Field Supplied)