Brochure

9
Features Chart/Explanation
Key Features (Standard Remote/7 Day Timer):
Thin and Easy To Read
Simple To Install and Use
Can Be Adapted for Use On All Indoor
Units
Fan Speed Control
Airflow Direction
Operating Mode (Heating/Cooling/Auto/Dry/Fan)
Vacation Mode for Continued Energy Efficiencies
Full 7 Day Set-Back Functionality, With Up To 6
Time Periods/Day
Full System Diagnostic Capability
(Diagnostic History Provides Immediate View of
System Past and Present.)
Key Features (Simple Remote):
Thin and Easy To Read
Simple To Install and Use
Can Be Adapted for Use On All 26,000
through 42,000 Utu/h Indoor Units.
Mode
Fan Speed Control
Set Temperature
On/Off
Airflow Direction
Perfectly Suited for Applications Where
Simpler Functionality is Required
(ie: Hotel Rooms, Nursing Homes, Offices)
Multiple Zone Controllers.
The Air Conditioning Gateway.
Panasonic’s system and intelligent controls
are the central nervous system to the
conditioning system. The gateway to all
data, temperature and system diagnostics.
The heart and soul of conditioning.
Key Features (System Control):
Controls Up To 64 Units Into 4
Individualized Zones
Alarm and Operational Signal Output
Single Access Points for All Connected
Wired Remotes
Remote Controller Options for Models 26,000 Btu’s and Larger
CZ-RELC2 (with Backlight)
CZ-RTC2 CZ-64ESMC1U
Applicable Unit
Wireless
Remote Controller
U1-
series
(Ceiling Recessed Type)
T1-
series
(Ceiling Suspended Type)
For All Large capacity series
Indoor Units
Built-in type
Signal receiving unit can be installed in the outer
panel of indoor unit.
Control panel can be installed in the inside indoor
unit.
External type
Separate type signal receiving unit.
Timer Remote Controller
(CZ-RTC2)
System Controller
(CZ-64ESMC1U)
Function
ON/OFF
l l
(Collective/Individual)
Operation
mode
switch
Heating
l l
(Individual)
Dry
l l
(Individual)
Cooling
l l
(Individual)
Fan
l l
(Individual)
Temp setting
l l
(Individual)
Fan speed setting (Hi/Mid./Lo/Auto)
l l
(Individual)
Auto flap Auto airflow direction setting
l l
Arbitrary airflow direction setting
l l
*
Sweep (Flap swing)
l l
*
Sensor temp. display
l 5
Self-diagnostic function
l l
System
Central control (at hand inhibited)
5 l
Group control
l
(Up to 8 units)
l
(Up to 64 groups)
Concurrent use with weekly timer
l l
Setting Range
Cooling, dry (˚F) 65 – 86
Heating (˚F) 61 – 79
CZ-RWSU2U CZ-RWSC1U
CZ-RWSK1U
K1-
series
Wired Remote Controllers (Except KE30/36NKU, KS30/36NKU)
Wireless Remote Controllers
Remote Controllers Functions
System Controller
Simplified Remote Controller
l
: Controllable
5
: Uncontrollable
Note:
If you use both remote controller and system
controller concurrently, both controllers can
be used on a last-signal priority basis.
Timer Remote Controller
NEW
CZ-RE2C2