11.2 Outdoor Unit
11.2.1 Select the Best Location
If an awning is built over the unit to prevent direct
sunli
ght or rain, be careful that heat radiat
ion from
the con
denser is not obstructed.
There should not be any animal or plant which
coul
d be affected by hot air discharged.
Keep the spaces indicated by arrows from
wall,
ceiling, fence or other obstacles.
Do not place any obstacles
which may cause a
sho
rt circuit of the discharged air.
If piping length is over the [piping length for
addition
al gas], additional refrigerant sh
ould be
adde
d as shown in the tabl
e.
Example: For E12***
If the unit is installed at 32.8 ft (10 m) distance, the
quantity of additional refrigerant should be 1.64 oz
(50 g) .... (32.8 - 24.6) ft x 0.2 oz/ft = 1.64 oz.
((10 - 7.5) m x 20 g/m = 50 g).
11.2.1.1 Indoor/Outdoor Installation
Diagram
11.2.2 Install the Outdoor Unit
After selecting the best location, start installation
according to Indoo
r/Outdoor Unit Installati
on
Diag
ram.
1 Fix the unit on concrete or rigid fram
e firmly
and ho
rizontally by bolt nut (ø10 mm).
2 When installing at roof, please consider strong
wind and earthquake.
Please fasten the installation stand firmly with
bolt or nails.
Model A B C D
E12***
22-7/16
"
(570 mm)
4-1/8"
(105 mm)
23/32"
(18.5 mm)
12-19/32
"
(320 mm)
E18***
24-1/8"
(613 mm)
5-5/32"
(131 mm)
5/8"
(16 mm)
14-3/16"
(360.5 mm)
Model
Capacity
(Btu/h)
Piping size
Std.
Length
Max.
Elevation
Min.
Piping
Length
Max.
Piping
Length
Additional
Refrigerant
Piping
Length for
add. gas
Gas Liquid
E12*** 11900
1/2"
(12.7mm)
1/4"
(6.35mm)
24.6 ft
(7.5 m)
49.2 ft
(15 m)
9.8 ft
(3 m)
65.6 ft
(20 m)
0.2 oz/ft
(20 g/m)
24.6 ft
(7.5 m)
E18*** 17500
49.2 ft
(15 m)
9.8 ft
(3 m)
100 ft
(30.5 m)
0.3 oz/ft
(25 g/m)
32.8 ft
(10 m)
Installation parts you
should purchase (
)
Sleeve ( )
Bend the pipe as
closely on the wall as
possible, but be careful
that it doesn’t break.
Putty (Gum Type Sealer) (
)
Bushing-Sleeve (
)
Vinyl tape (Wide) (
)
• Apply after carrying
out a drainage test.
Additional drain
hose (
)
1/4" Liquid side
piping (
)
Gas side piping (
)
Connection cable (
)
Saddle (
)
Power supply cable (
)
1
1
1
3
/
1
6
"
(3
0
0
m
m
)
o
r
m
o
r
e
3
1
5
/
1
6
"
(
1
0
0
m
m
)
o
r
m
o
r
e
3
1
5
/
1
6
"
(
1
0
0
m
m
)
o
r
m
o
r
e
3
9
3
/
8
"
(
1
0
0
0
m
m
)
o
r
m
o
r
e
Itisadvisabletoavoid
more than 2 blockage
directions. For better
ventilation & multiple-
outdoor installation,
please consult
authorized dealer/
specialist.
•
This illustration is for explanation purposes only.
The indoo r u nit w ill actually face a different way.
a
Indoor unit
b
Outdoor
unit
Rem ote control holder
Remote control holder fixing screws
Remote
control
Attaching the remote control holder to the wall
8ft(2.4m)
or more
FloororGradelevel