Operating Instructions Air Conditioner Model No. Indoor Unit Outdoor Unit CS-E7PKR CS-E9PKR CS-E12PKR CS-E15PKR CS-E18PKR CS-E21PKR CS-E24PKR CS-E28PKR CU-E7PKR CU-E9PKR CU-E12PKR CU-E15PKR CU-E18PKR CU-E21PKR CU-E24PKR CU-E28PKR AAF Thank you for purchasing Panasonic Air Conditioner. Installation instructions attached. Before operating the unit, read these operating instructions thoroughly and keep them for future reference. English Operating Instructions Air Conditioner F569361 F569361_EN.
Qu Provide maximum comfort, clean air and optimise energy saving 3 ECONAVI and AUTO COMFORT Equipped with the human activity sensor, the air conditioner ensures to deliver cool or warm air to you, and keeps the room consistently comfortable with minimum energy consumption. See “To learn more...” for details. 1 nanoe-G Deactivates harmful micro-organisms such as viruses, bacteria, etc. to keep air clean. It also deactivates viruses and bacteria on the filter to keep inside of the unit clean.
Quick guide Inserting the batteries 1 2 3 1 Pull out the back cover of remote control 2 Insert AAA or R03 batteries (can be used ~ 1 year) 3 Close the cover 2 you, 3 1 Clock setting Table of contents Safety precautions ...................4-5 How to use...............................6-7 To learn more... ......................8-9 Cleaning instructions ................ 10 1 Press CLOCK Troubleshooting ....................... 11 2 Set the time Information.................
Safety precautions To prevent personal injury, injury to others or property damage, please comply with the following: Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classified as below: WARNING This sign warns of death or serious injury. CAUTION This sign warns of injury or damage to property. The instructions to be followed are classified by the following symbols: This symbol denotes an action that is PROHIBITED.
ning, it for a This equipment must be earthed to prevent electrical shock or fire. play om Prevent electric shock by switching off the power supply and unplug: - Before cleaning or servicing, - When extended non-use, or - During abnormally strong lightning activity. CAUTION Indoor unit and outdoor unit Do not wash the indoor unit with water, benzine, thinner or scouring powder to avoid damage or corrosion at the unit. Do not touch the sharp aluminium fin, sharp parts may cause injury.
How to use AUTO COMFORT ECONAVI To optimise energy saving MODE To select operation mode AUTO - For your convenience HEAT - To enjoy warm air COOL - To enjoy cool air DRY - To dehumidify the environment FAN - To circulate air in the room Human activity sensor and indicator NANOE-G Indicator (Green) (Green) (Orange) (Green) (Blue) (Orange) (Green) POWER Remote control display TIMER AUTO COMFORT NANOE-G POWERFUL AIR CONDITIONER MODE MILD DRY AUT Sunlight sensor and remote control receiver MILD
See “To learn more...” for details. AUTO COMFORT To maximise comfort AUTO COMFORT NANOE-G To purify the air • Can be activated even when the unit is turned off. In this condition, the unit will operate as a fan with AUTO fan speed and louver swing. To deactivate viruses/bacteria on the filter 3 1 Select ON or OFF timer • Each time pressed: POWER • After the unit is turned off, the nanoe-G in-filter deactivation may activate up to 150 minutes. Turning on the unit cancels this operation.
To learn more... Operation mode The h AUTO : During operation mode selection the POWER indicator blinks. • Unit selects operation mode every 10 minutes according to setting temperature and room temperature. HEAT : Unit takes a while to warm up. The POWER indicator blinks during this operation. COOL : Use curtains to screen off sunlight and outdoor heat to reduce power consumption during COOL mode. DRY : Unit operates at low fan speed to give a gentle cooling operation.
The human activity sensor will also scan for area of heat source and movement in a room. Detection area Human activity indicator 120º 7m At left area after his tes lected, FORT At center / multiple area At right area The unit judges human activity area for a few seconds before indicator updates. Based on area activeness horizontal airflow direction louver will adjust either fix at predetermined position or swing left/right periodically.
Cleaning instructions To ensure optimal performance of the unit, cleaning has to be carried out at regular intervals. Dirty unit may cause malfunction and you may see error code “H99”. Please consult authorised dealer. • Switch off the power supply and unplug before cleaning. • Do not touch the aluminium fin, sharp parts may cause injury. • Do not use benzine, thinner or scouring powder. • Use only soap ( pH 7) or neutral household detergent. • Do not use water hotter than 40 °C.
Troubleshooting The following symptoms do not indicate malfunction. Symptom Indoor fan stops occasionally during automatic fan speed setting. Airflow continues even after operation has stopped. • Extraction of remaining heat from the indoor unit (maximum 30 seconds). Operation is delayed a few minutes after restarting. • The delay is a protection to the unit’s compressor. Outdoor unit emits water/steam. • Condensation or evaporation occurs on pipes. TIMER indicator is always on.
Information English Information for Users on Collection and Disposal of Old Equipment and used Batteries [Information on Disposal in other Countries outside the European Union] These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal. Note for the battery symbol (bottom two symbol examples): This symbol might be used in combination with a chemical symbol.