Performance Data @ ARI Standard Conditions
High Heat @
17F
Low Heat @
5F
20,400BTU
Cooling
Total Capacity (BTU/H)
17.200
(
5,800
-19
,800
)
Sensible Capacity (BTU/H)
Latent Capacity (BTU/H)
SEER
21
Dehumidification (Pints/H)
3.6
Amps (A)
6.3
Power Input (W)
1.30K
Outdoor Sound Rating (dB-A)
52
Heating
Total Capacity (BTU/H)
18,000 (3,300-24,000)
HSPF
12
Amps (A)
6.7
Power Input (W)
1.63K
Outdoor Sounds Rating (dB-A)
54
Features
Controls
Microprocessor
Remote Controller
LCD Wireless Type included as
standard
Wired Remote Controller
Optional
Temperature Control
IC Thermistor
Timer
Single Event Daily ON/OFF TIMER
Quiet mode
Included
High Power mode
Included
Air Louver, Horizontal
Automatic, Sweep, Step
Air Louver, Vertical
Automatic, Sweep, Step
Power Failure Automatic Restart
Built-In
Heating/Cooling Automatic
Changeover
Built-In
Self-Diagnosis
Built-In
Air Filter
Washable, One-touch
Room Freeze Protection
Operating Range
Indoor Air Intake Temp
Outdoor Air Intake Temp
Cooling (Max)
89.6F DB/73.4F WB
114.8F DB
Cooling (Min)
60.8F DB/51.8F WB
0F DB
Heating (Max)
86.0F DB
75.2F DB/64.4F WB
Heating (Min)
60.8 DB
-15.0F DB/-2.2F WB