Submittal
Table Of Contents
Split System Submittal Data
System: XE18WKUA Indoor: CS-XE18WKUAW Outdoor: CU-XE18WKUA Single
Zone Heat Pump Wall Mounted
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Approval:
Date:
Construction:
Unit#:
Drawing#:
General Data
Power (V/P/Hz)
230/208/1/60
Circuit Ampacity (A)
20
Fuse Size, Max. (A)
25
Compressor
No. Used
1
Motor Type (No. of poles)
Rotary
Output Power (W)
1.70K
Outdoor Unit
Fan Type
Propeller Fan
No. Speeds
Variable
Type Drive
DC
No. Poles (RPM)
8 (
640
)
No. Motors (W)
60
CFM (Hi speed)
Coil Type
Aluminum / Blue Coated
Fin Type - Pipe Type
Corrugated Fin
Rows x stage x F.P.I.
2 X 36 X 19
Size (W x H x L) MM
36.4X756X868.6
Tube Size (in.)
Indoor Unit
Fan Type
Cross-Flow Fan
Motor Type, No. of Poles
DC / Poles
No. Speeds
5
RPM (Cool / Heat), High
1310/1380
No. Motors (W)
1 (
30
)
CFM (Qlo/Lo/Me/Hi/SHi) Cooling
384/424/493/560/586
CFM (Qlo/Lo/Me/Hi/SHi) Heating
386/425/508/595/621
Operating Sound-H/L/QLo/ dB-A
(Cool)
47/39/36
Operating Sound-H/L/QLo/ dB-A
(Heat)
48/39/36
Coil Type
Fin Type - Pipe Type
Aluminum Precoat / Slit Fin
Row x stage x FPI
2 x 17 x 21
Size
836.5 X 357 X 25.4
Tube Size (in.)
Drain Connection Size Inner
Diameter
3/4 VIA INCLUDED ADAPTER
Refrigerant
OZ. - R410a (outdoor unit)
65.3
Refrigerant Control
Expansion Valve
Refrigerant Tubing Connections
Flare
Line Length, Max (ft.)
100
Elevation Difference, Max (ft.)
50
Line Size (in. O.D. Discharge)
1/4
Line Size (in. O.D. Suction)
1/2
Pre-charge, tubing length at
shipment
25
Dimensions (H x W x D)
Indoor Unit (UnCrated) (in.)
11-29/32 X 43-13/32 X 9-5/8
Outdoor Unit (Uncrated) (in.)
231-5/16 X 34-15/32 X 12-5/8
Weight (lbs.)
(Indoor) Net
33 lbs
(Outdoor) Net
132 lbs