Owners Manual

72
13.11 nanoe™ X Operation
Generate nanoe™ X (water wrapped ion particle) to moisturize skin, provide deodorization & sterilization effect.
nanoe™ X operation start condition
o During unit running at any operation mode, if nanoe™ X operation is activated, combination operation
(operation mode + nanoe™ X operation) starts.
o During unit is OFF, if nanoe™ X operation is activated, nanoe™ X individual operation starts.
nanoe™ X operation stop condition
o When OFF/ON button is pressed to stop the operation.
o When nanoe™ X button is pressed.
o When OFF Timer activates.
nanoe™ X operation pause condition
o When indoor fan stop (during deice, odor cut control, thermostat off, etc.). nanoe™ X operation resume after
indoor fan restarts.
o When indoor intake temperature 35°C and 5°C. nanoe™ X operation resume after indoor intake
temperature < 35°C or 5°C continuously for 6 minutes.
Indoor fan control
o During any operation mode combines with nanoe™ X operation, fan speed follows respective operation
mode. However, nanoe™ X system enabled when fan speed 360 rpm to ensure proper negative ion
distribution, nanoe™ X system disabled when fan speed < 360 rpm.
o During nanoe™ X individual operation, fan speed follow remote control setting. Auto Fan Speed for nanoe™
X individual operation is cooling medium fan. Powerful & Quiet is disabled during nanoe™ X.
Airflow direction control
o During any operation mode combines with nanoe™ X operation, airflow direction follows respective operation
mode.
o During nanoe™ X individual operation, Air Swing follow remote control setting.
Timer control
o When ON Timer activates when unit stops, previous operation resumes and restored last saved nanoe™ X
operation status.
o When ON Timer activates during any operation, no change on current operation.
o When OFF Timer activates during any operation, all operation stops and the latest nanoe™ X operation
status is saved.
Indicator
o When nanoe™ X starts, nanoe™ X indicator ON.
Remote control receiving sound
o Normal operation nanoe™ X Operation : Beep
o nanoe™ X Operation Normal operation : Beep
o Stop nanoe™ X individual Operat : Beep
o nanoe™ X individual Operation Stop : Long Beep
Power failure
o During nanoe™ X individual operation, if power failure occurs, after power resumes, nanoe™ X individual
operation resumes immediately.
o During combination operation, if power failure occurs, after power resumes, combination operation resume
immediately.