13.4.1.2 CS-XE18WKUAW CS-XE24WKUAW
Operation Mode Airflow Direction
Inner Vane Angle (°) Outer Vane Angle (°)
1 2 3 4 5 1 2 3 4 5
Cooling
Auto 140 ~ 90 47 ~ 74
Manual 140 135 120 105 90 47 58 64 69 74
Soft Dry
Auto 140 ~ 90 47 ~ 74
Manual 140 135 120 105 90 47 58 64 69 74
Heating
Auto
A 140 50
B 90 78
C 135 58
Manual 140 135 112 90 80 50 58 69 78 90
1. Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the
angles as stated above. For heating mode operation, the angle of the vane depends on the indoor heat
exchanger temperature as Figure 1 below. It does not swing during fan motor stop. When the air conditioner is
stopped using remote control, the vane will shift to close position.
2. Manual vertical airflow direction can be set using remote control; the angles of the vane are as stated above and
the positions of the vane are as Figure 2 below. When the air conditioner is stopped using remote control, the
vane will shift to close position.
* The horizontal vane angle tolerance is within +/- 5 degree.
Side View (Inner Vane)
Reference point
Stopper
Closed
Position
Step 1
148º
Step 2
Step 3
Step 4
Step 5
Figure 2
Side View (Outer Vane)
Stopper
Closed
Position
Step 1
Step 2
Step 3
Step 4
Step 5
Reference point
101º