Submittal
13
5. Dimensions
5.1 Indoor Unit
<Top View>
<Front View>
<Bottom View>
<Rear View>
Relative position between the indoor unit and the installation plate <Front View>
Gas side
Liquid side
<Side View> <Side View>
Right
piping
hole
Left
piping
hole
Indoor unit
external
dimensions
line
Installation
plate
Unit : inch (mm)
41/64 (16.5)
1-11/16 (43)
3-3/4 (95)
10-1/6 (255)
1/16-3/32 (1-2) 1/16-3/32 (1-2)
Left piping
hole
Air outlet
direction
Air intake
direction
Right piping
hole
4-3/4 (119.1)
4-1/32 (105.8)
2-3/16 (60) 2-3/16 (60)
10-1/16 (255)
11-5/8 (295)
2-3/16 (60)
1-11/16 (41.5)
16-3/16 (410)
10-3/16 (264.2)
1-5/8-2-7/16 (41-61)
3-7/16 (87)
2-17/32 (64)
<Remote Control Holder>
<Remote Control>
6-5/16 (160)
2-5/16 (59)
7/8 (22)
19-19/32 (497.2)
34-9/32 (870)
5-1/16 (128)
5-1/16 (128) 5-1/16 (128)
9-17/32 (241.5) 9-17/32 (241.5)
17 (432)17-9/32 (439)
CLOCK
AIRCONDITIONER
OFF/ON
SET CHECK RESET
AC
RC
ON
OFF
SET
123
TIMER
AUTO
COM FORT
POWERFUL/
QUIET
MODE
TEMP
FAN SPEED
AIR SW ING
ECON AVI
RFP
MODE
O
FF/ON
CHECK
O
N
O
FF
S
ET
1
2
3
T
I
M
E
R
T
E
M
P
CANCEL
Panasonic North America
Air Conditioning Division
1690 Roberts Blvd., NW, Suite 110
Kennesaw, GA 30144
business.panasonic.com/hvac
Indoor Dimensions
Outdoor Dimensions
14
5.2 Outdoor Unit
Unit: inch (mm)
<Side View> <Front View>
<
T
o
p
V
ie
w
>
<Side View>
34-15/32 (875)
1-3/8 (34.5)
3/8 (9.5)
2-31/32 (75)
2-25/32 (70.4)
63/64 (25)
5-3/16 (131)
24-5/32 (613)
5-3/16 (131)
1-1/2 (38)
5-31/32 (151)
14-7/32 (360.5)
27-3/8 (695)
3-5/32 (85)
2-25/32 (70)
1-3/16 (30)
12-5/8 (320)
2-way valve at Liquid side
(High Pressure)
3-way valve at Gas side
(Low Pressure)
Anchor Bolt Pitch
14-7/32 (360.5) x 24-5/32 (613)
Space necessary for
installation
3-15/16 (10 cm)
43 (100 cm)
3-15/16 (10 cm)
13
5. Dimensions
5.1 Indoor Unit
<Top View>
<Front View>
<Bottom View>
<Rear View>
Relative position between the indoor unit and the installation plate <Front View>
Gas side
Liquid side
<Side View> <Side View>
Right
piping
hole
Left
piping
hole
Indoor unit
external
dimensions
line
Installation
plate
Unit : inch (mm)
41/64 (16.5)
1-11/16 (43)
3-3/4 (95)
10-1/6 (255)
1/16-3/32 (1-2) 1/16-3/32 (1-2)
Left piping
hole
Air outlet
direction
Air intake
direction
Right piping
hole
4-3/4 (119.1)
4-1/32 (105.8)
2-3/16 (60) 2-3/16 (60)
10-1/16 (255)
11-5/8 (295)
2-3/16 (60)
1-11/16 (41.5)
16-3/16 (410)
10-3/16 (264.2)
1-5/8-2-7/16 (41-61)
3-7/16 (87)
2-17/32 (64)
<Remote Control Holder>
<Remote Control>
6-5/16 (160)
2-5/16 (59)
7/8 (22)
19-19/32 (497.2)
34-9/32 (870)
5-1/16 (128)
5-1/16 (128) 5-1/16 (128)
9-17/32 (241.5) 9-17/32 (241.5)
17 (432)17-9/32 (439)
CLOCK
AIRCONDITIONER
OFF/ON
SET CHECK RESET
AC
RC
ON
OFF
SET
123
TIMER
AUTO
COM FORT
POWERFUL/
QUIET
MODE
TEMP
FAN SPEED
AIR SW ING
ECON AVI
RFP
MODE
O
FF/ON
CHECK
O
N
O
FF
S
ET
1
2
3
T
I
M
E
R
T
E
M
P
CANCEL