Datasheet
6,50 A++
SEER
SEASONAL ENERGY
EFFICIENCY RATIO
Prevention
allergen filter
ANTI BACTERIAL
FILTER
MRE Multi Inverter models are powerful and efficient and are always there when you need them.
Furthermore, with the Anti Bacterial Filter, you can always enjoy the best quality air, without viruses, moulds or
bacteria.
MRE WALL MOUNTED 2x1
STANDARD INVERTER
Energy
saving
4,00 A+
SCOP
SEASONAL COEFFICIENT
OF PERFORMANCE
Kit KIT-2MRE77-PBE KIT-2MRE79-PBE KIT-2MRE712-PBE KIT-2MRE99-PBE KIT-2MRE77-PKE KIT-2MRE79-PKE
Indoor CS-MRE7PKE CS-MRE7PKE CS-MRE7PKE CS-MRE9PKE CS-MRE7PKE CS-MRE7PKE
CS-MRE7PKE CS-MRE9PKE CS-MRE12PKE CS-MRE9PKE CS-MRE7PKE CS-MRE9PKE
Outdoor CU-2RE15PBE CU-2RE15PBE CU-2RE15PBE CU-2RE15PBE CU-2RE18PBE CU-2RE18PBE
Cooling capacity Nominal (Min - Max) kW 4,00 (1,50 - 4,60) 4,40 (1,50 - 4,80) 4,40 (1,50 - 4,80) 4,40 (1,50 - 4,80) 4,00 (1,50 - 4,60) 4,50 (1,50 - 4,80)
Nominal (Min - Max) kCal/h 3.440 (1.290 - 3.956) 3.784 (1.290 - 4.128) 3.784 (1.290 - 4.128) 3.784 (1.290 - 4.128) 3.440 (1.290 - 3.956) 3.870 (1.290 - 4.128)
Cooling capacity room A Nominal kW 2,00 1,95 1,70 2,20 2,00 2,00
Cooling capacity room B Nominal kW 2,00 2,45 2,70 2,20 2,00 2,50
SEER Nominal Energy Saving
6,30 i 6,50 i 6,50 i 6,50 i 6,10 i 6,30 i
Pdesign (cooling) kW 4,40 4,40 4,40 4,40 4,80 4,80
Power input cooling Nominal (Min - Max) kW 1,170 (0,270 - 1,340) 1,300 (0,270 - 1,520) 1,300 (0,270 - 1,520) 1,300 (0,270 - 1,520) 1,160 (0,270 - 1,340) 1,400 (0,270 - 1,510)
Annual electricity consumption (cooling)
1)
kWh/a 237 237 237 237
Heating capacity Nominal (Min - Max) kW 4,80 (1,10 - 6,30) 4,80 (1,10 - 6,30) 4,80 (1,10 - 6,50) 4,80 (1,10 - 6,50) 5,20 (1,10 - 6,30) 5,20 (1,10 - 6,30)
Nominal (Min - Max) kCal/h 4.128 (946 - 5.418) 4.128 (946 - 5.418) 4.128 (946 - 5.590) 4.128 (946 - 5.590) 4.472 (946 - 5.418) 4.472 (946 - 5.418)
Heating capacity at -7°C Nominal kW 3.220 3.220 3.220 3.220 3.540 3.540
Heating capacity room A Nominal kW 2,40 2,15 1,85 2,40 2,60 2,60
Heating capacity room B Nominal kW 2,40 2,65 2,95 2,40 2,60 2,90
SCOP Nominal Energy Saving
3,80 a 4,00 h 4,00 h 4,00 h 3,80 a 3,80 a
Pdesign at -10°C kW 3,60 3,60 3,60 3,60 3,80 3,80
Power input heating Nominal (Min - Max) kW 1,200 (0,240 - 1,610) 1,200 (0,240 - 1,610) 1,200 (0,240 - 1,670) 1,200 (0,240 - 1,670) 1,300 (0,240 - 1,610) 1,300 (0,240 - 1,610)
Annual electricity consumption (heating)
1)
kWh/a 1.260 1.260 1.260 1.260
Indoor unit
Connection mm² 4 x 1,5 4 x 1,5 4 x 1,5 4 x 1,5 4 x 1,5 4 x 1,5
Current (Nominal) Cooling / Heating A 5,45 / 5,35 6,10 / 5,35 6,10 / 5,35 6,10 / 5,35 5,45 / 5,80 6,10 / 5,80
Air volume Cooling m³/h 606 (E7) / 606 (E7) 606 (E7) / 618 (E9) 606 (E7) / 654 (E12) 618 (E9) / 618 (E9) 606 (E7) / 606 (E7) 606 (E7) / 618 (E9)
Moisture removal volume Cooling l/h 1,3 (E7) / 1,3 (E7) 1,3 (E7) / 1,5 (E9) 1,1 (E7) / 1,6 (E12) 1,4 (E9) / 1,4 (E9) 1,3 (E7) 1,3 (E7) / 1,5 (E9)
Sound pressure level
2)
Cooling & Heating (Lo) dB(A) 29 (E7) / 29 (E7) 29 (E7) / 29 (E9) 29 (E7) / 32 (E12) 29 (E9) / 29 (E9) 29 (E7) / 29 (E7) 29 (E7) / 29 (E9)
Sound power level Cooling & Heating (Hi) dB 56 (E7) / 56 (E7) 56 (E7) / 56 (E9) 56 (E7) / 60 (E12) 56 (E9) / 56 (E9) 56 (E7) / 56 (E7) 56 (E7) / 56 (E9)
Dimensions H x W x D mm 290 x 870 x 214 290 x 870 x 214 290 x 870 x 214 290 x 870 x 214 290 x 870 x 214 290 x 870 x 214
Net weight kg 9 9 9 9 9 9
Air purifier filter Anti Bacterial Filter Anti Bacterial Filter Anti Bacterial Filter Anti Bacterial Filter Anti Bacterial Filter Anti Bacterial Filter
Outdoor unit
Power source V 230 230 230 230 230 230
Recommended fuse A 16 16 16 16 16 16
Recommended power cable section mm² 1,5 1,5 1,5 1,5 1,5 1,5
Air volume Cooling / Heating m³/h 1.962 / 1.962 1.962 / 1.962 1.962 / 1.962 1.962 / 1.962 2.214 / 2.416 2.214 / 2.416
Sound pressure level
2)
Cooling / Heating (Hi) dB(A) 47 / 49 47 / 49 47 / 49 47 / 49 49 / 51 49 / 51
Sound power level Cooling / Heating (Hi) dB 62 / 64 62 / 64 62 / 64 62 / 64 64 / 66 64 / 66
Dimensions
3)
H x W x D mm 619 x 824 x 299 619 x 824 x 299 619 x 824 x 299 619 x 824 x 299 619 x 824 x 299 619 x 824 x 299
Net weight kg 39 39 39 39 39 39
Piping connections Liquid pipe / Gas pipe inch (mm) 1/4 (6,35) / 3/8 (9,52) 1/4 (6,35) / 3/8 (9,52) 1/4 (6,35) / 3/8 (9,52) 1/4 (6,35) / 3/8 (9,52) 1/4 (6,35) / 3/8 (9,52) 1/4 (6,35) / 3/8 (9,52)
Refrigerent Loading R410A kg 39 1,45 1,45 1,45 1,45 1,45
Elevation difference (in/out)
4)
Maxm101010101010
Piping length (total) Min / Max m 3 / 30 3 / 30 3 / 30 3 / 30 3 / 30 3 / 30
Piping length (one unit) Min / Max m 3 / 20 3 / 20 3 / 20 3 / 20 3 / 20 3 / 20
Precharge length Max m 20 20 20 20 20 20
Additional charge g/m 20 20 20 20 20 20
Operating range Cooling Min / Max °C 16 / 43 16 / 43 16 / 43 16 / 43 16 / 43 16 / 43
Heating Min / Max °C -10 / 24 -10 / 24 -10 / 24 -10 / 24 -10 / 24 -10 / 24
Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb)
1) The annual energy consumption is calculated in accordance with the ErP directive. 2) The Sound pressure level of the units shows the value measured of a position 1 metre in front of the main body and 0,8 m below the unit. The sound pressure is measured in
accordance with Eurovent 6/C/006-97 specification. 3) Add 70 mm for piping port. 4) When installing the outdoor unit at a higher position than the indoor unit.
Specifications subject to change without notice.
For detailed information about ErP, please visit our page http://www.ptc.panasonic.eu
Down to
-10 ºC in
heating mode
OUTDOOR
TEMPERATURE
Possible
to use on
R22 pipings
R22 RENEWAL
5 year
compressor
warranty
60