Datasheet
Possible
to use on
R22 pipings
R22 RENEWAL
Prevention
allergen filter
ANTI BACTERIAL
FILTER
6,10 A++
SEER
SEASONAL ENERGY
EFFICIENCY RATIO
SUPER QUIET
Silent air
22 dB
4,00 A+
SCOP
SEASONAL COEFFICIENT
OF PERFORMANCE
RE Inverter models are powerful and efficient, with an outstanding energy ranking of A++/A+, unique in the
market! The RE works up to an outdoor temperature of -15°C in heating mode and -10°C up a outdoor
temperature of -15°C in heating and -10 in cooling and still with a high efficiency and capacity! Furthermore,
the annual energy consumption has never been so low.
RE has a unique Anti Bacterial Filter in order to enjoy the best quality air, without viruses, mould or bacteria.
WALL MOUNTED RE TYPE
STANDARD INVERTER
SEER and SCOP: For KIT-RE9-QKE and KIT-RE12-QKE. SUPER QUIET: For RE9 and RE12.
Energy
saving
Kit KIT-RE9-QKE KIT-RE12-QKE KIT-RE15-QKE KIT-RE18-QKE KIT-RE24-QKE
Indoor CS-RE9QKE CS-RE12QKE CS-RE15QKE CS-RE18QKE CS-RE24QKE
Outdoor CU-RE9QKE CU-RE12QKE CU-RE15QKE CU-RE18QKE CU-RE24QKE
Cooling capacity Nominal (Min - Max) kW 2,50 (0,85 - 3,00) 3,50 (0,85 - 3,90) 4,20 (0,85 - 4,60) 5,00 (0,98 - 6,00) 6,80 (0,98 - 8,10)
Nominal (Min - Max) kCal/h 2.150 (730 - 2.580) 3.010 (730 - 3.350) 3.610 (730 - 3.960) 4.300 (840 - 5.160) 5.850 (840 - 6.970)
SEER Nominal Energy Saving
6,10 i 6,10 i 5,60 h 6,70 i 6,00 h
Pdesign (cooling) kW 2,5 3,5 4,2 5,0 6,8
Power input cooling Nominal (Min - Max) kW 0,670 (0,250 - 0,950) 1,000 (0,255 - 1,190) 1,260 (0,265 - 1,650) 1,470 (0,280 - 2,030) 2,100 (0,380 - 2,670)
Annual electricity consumption (cooling)
1)
kWh/a 143 201 263 261 397
Heating capacity Nominal (Min - Max) kW 3,30 (0,80 - 4,10) 4,00 (0,80 - 5,10) 5,00 (0,80 - 6,80) 5,80 (0,98 - 8,00) 8,60 (0,98 - 9,90)
Nominal (Min - Max) kCal/h 2.840 (690 - 3.530) 3.440 (690 - 4.390) 4.300 (690 - 5.850) 4.990 (840 - 6.880) 7.400 (840 - 8.510)
Heating capacity at -7°C Nominal kW 2,7 3,30 3,9 4,98 6,13
SCOP Nominal Energy Saving
4,00 h 4,00 h 3,80 a 4,10 h 3,80 a
Pdesign at -10°C kW 2,4 2,8 3,6 4,4 5,5
Power input heating Nominal (Min - Max) kW 0,800 (0,195 - 1,130) 1,050 (0,200 - 1,420) 1,350 (0,200 - 2,050) 1,540 (0,340 - 2,600) 2,610 (0,450 - 3,130)
Annual electricity consumption (heating)
1)
kWh/a 840 980 1.326 1.502 2.026
Indoor Unit
Power source V 230 230 230 230 230
Recommended fuse A 16 16 16 16 16
Recommended power cable section mm² 1,5 1,5 2,5 2,5 2,5
Connection (indoor/outdoor) mm² 4 x 1,5 4 x 1,5 4 x 1,5 4 x 1,5 4 x 1,5
Current (Nominal) Cooling / Heating A 2,95 / 3,55 4,00 / 4,60 5,60 / 6,00 6,60 / 6,90 9,60 / 11,70
Maximum current A 5,0 6,2 9,2 11,4 14,5
Air volume Cooling / Heating m³/h 702 / 768 738 / 768 750 / 804 978 / 1.074 1.104 / 1.170
Moisture removal volume l/h 1,5 2 2,4 2,8 3,9
Sound pressure level
2)
Cooling (Hi / Lo / Q-Lo) dB(A) 41 / 26 / 22 42 / 30 / 22 44 / 31 / 29 44 / 37 / - 47 / 38 / -
Heating (Hi / Lo / Q-Lo) dB(A) 41 / 27 / 25 42 / 33 / 25 44 / 35 / 28 44 / 37 / - 47 / 38 / -
Sound power level Cooling (Hi) dB 57 58 60 60 63
Heating (Hi) dB 57 58 60 60 63
Dimensions H x W x D mm 290 x 870 x 214 290 x 870 x 214 290 x 870 x 214 290 x 1.070 x 240 290 x 1.070 x 240
Net weight kg 9 9 9 12 12
Air purifier filter Anti Bacterial Filter Anti Bacterial Filter Anti Bacterial Filter Anti Bacterial Filter Anti Bacterial Filter
Silver decoration sheet Yes Yes Yes Yes Yes
Outdoor Unit
Air volume Cooling / Heating m³/h 1.788 / 1.740 1.998 / 1.998 1.998 / 1.998 2.064 / 2.040 3.012 / 3.012
Sound pressure level
2)
Cooling (Hi) dB(A) 47 48 49 47 52
Heating (Hi) dB(A) 48 50 51 47 52
Sound power level Cooling (Hi) dB 62 63 64 61 66
Heating (Hi) dB 63 65 66 61 66
Dimensions
3)
H x W x D mm 542 x 780 x 289 619 x 824 x 299 619 x 824 x 299 695 x 875 320 795 x 875 x 320
Net weight kg 33 34 34 46 67
Piping connections Liquid / Gas pipe inch (mm) 1/4 (6,35) / 3/8 (9,52) 1/4 (6,35) / 3/8 (9,52) 1/4 (6,35) / 1/2 (12,70) 1/4 (6,35) / 1/2 (12,70) 1/4 (6,35) / 5/8 (15,88)
Refrigerant loading R410A kg 0,97 1,02 1,02 1,22 1,80
Elevation difference (in/out) Max m 15 15 15 15 20
Piping length Min / Max m 3 / 15 3 / 15 3 / 15 3 / 20 3 / 30
Precharge length Max m 7,5 7,5 7,5 7,5 10,0
Additional charge g/m 20 20 20 20 30
Operating range Cooling Min / Max °C -10 / +43 -10 / +43 -10 / +43 -10 / +43 -10 / +43
Heating Min / Max °C -15 / +24 -15 / +24 -15 / +24 -15 / +24 -15 / +24
Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb)
Connectivity restriction: JKE units are not compatible with QKE units.
1) The annual energy consumption is calculated in accordance with the ErP directive. 2) The Sound pressure level of the units shows the value measured of a position 1 metre in front of the main body and 0,8 m below the unit. The sound pressure is measured in
accordance with Eurovent 6/C/006-97 specification. Q-Lo: The lowest fan speed. Lo: The second lowest fan speed (the lowest fan speed for RE18/24). 3) Add 70 mm for piping port.
Specifications subject to change without notice.
For detailed information about ErP, please visit our page http://www.ptc.panasonic.eu
5 year
compressor
warranty