Owner manual
4
   PRODUCT OVERVIEW & OPERATIONS  PRODUCT OVERVIEW & OPERATIONS
Front panel
Receiver
Auto OFF/ON button
•  Used when remote control is misplaced 
or malfunction.
Action Mode
Press once. Auto
Press and hold until 1 beep is 
heard, then release.
Cooling
Press the button to turn off.
e-ion AIR PURIFYING SYSTEM
Do not touch during operation
e-ion fi lters e-ion charging wire Active e-ion Generator
Maximum 
distances: 8m
Horizontal airfl ow 
direction louver
• Manually 
adjustable.
Vertical airfl ow 
direction louver
•  Do not adjust 
by hand.
Remote control 
display
INDICATOR
(Red/Orange/Blue)
(Green)
(Orange)
(Orange)
(Orange)
(Blue)
TO TURN ON OR OFF THE UNIT
POWE
R
•  Please be aware of the OFF indication on the remote control 
display to prevent the unit from starting/stopping improperly.
TO SET TEMPERATURE
•  For heat, cool and dry modes, the range of temperature for 
selection is 16°C ~ 30°C.
•  Operating the unit within the recommended temperature could 
induce energy saving.
  HEAT mode : 20˚C ~ 24˚C.
COOL mode : 26˚C ~ 28˚C.
DRY mode : 1˚C ~ 2˚C lower than room temperature.
TO SELECT OPERATION MODE
AUTO mode - For your convenience
•  Unit selects the operation mode according to the room 
temperature.
•  Once auto mode is selected, the unit will operate at the standard 
setting temperature.
• To change the standard setting temperature, press 
 for “HI” 
or   for “LO”.
Room 
temperature
Operation 
mode
Standard setting 
temperature
HI 
(+2°C)
LO 
(-2°C)
23°C & above Cool 25°C 27°C 23°C
Below 23°C Dry 22°C 24°C 20°C
Below 20°C Heat 21°C 23°C 19°C
HEAT mode - To enjoy warm air
•  In heat mode, it takes a while for the unit to warm up. The power 
indicator blinks during this operation.
COOL mode - To enjoy cool air
DRY mode - To dehumidify the environment
•  Unit operates at low fan speed to give a gentle cooling operation.