Datasheet
PM
U-shaped Micro Photoelectric Sensor
Extremely small size
enables space saving
and quick installation!
302
SERIES
Extremely small
Conventional
model
Ultra-small type
PM-K24(-R)
Small cable type
PM-K44
Equipped with two independent outputs
All models are equipped with two independent outputsLight-ON and Dark-ON.
Hence, one model suffices even if the output is to be used differently, depending
upon the location of use.
Also, since two independent outputs have been provided, cumbersome handling
of the output conversion control input, or fear of logic inversion due to a cable
break, is eliminated. The sensor can be connected to the existing wiring as it is.
Quick fitting hook-up connector
Easy to maintain connector type models
are available. Its exclusive connector is
the industry’s first hook-up connector.
Since only crimping with exclusive pliers
is to be done, cumbersome soldering or
insulation is absolutely not required.
Further, connector attached cable is
also available.
Wide model variety
A wide variety of 17 shapes and 34
models is available. You may select
from this wide range to suit the
mounting conditions.
Crimp the connector
on the cable.
Quick connection to
the sensor.
Note: Ensure to insulate the unused output wire.
Meets global requirements
Conforms to Europe’s EMC Directive
and obtains UL Recognition.
Both, NPN and PNP output models are
available.
Ultra-small type PM-24(-R) contributes to the miniaturization of your equipment.
Even the small cable type has become very compact.
08/2005