Dual Display Digital Pressure Sensor DP-100 SERIES
668
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Other Products
DP-100
DP-M
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
APPLICATIONS
Conrming suction of electronic component
Conrming reference pressure Air-leak test for PET bottles
All models in the line-up are compound pressure types
No sensor settings are required to switch between positive pressure and negative
pressure, so that the number of registered part numbers can be decreased.
BASIC PERFORMANCE
FUNCTIONS
High performance accomplished
The low pressure type displays measurements in 0.1 kPa
at a resolution of 1/2,000 and has a response time of 2.5
ms (variable up to 5,000 ms), ±0.5 % F.S. temperature
characteristics and ±0.1 % F.S. repeatability, giving it
high performance.
Low pressure type
For low
pressure
<
For low pressure
>
For high
pressure
DP-101
DP-102
–100 kPa 100 kPa
1 MPa
0 kPa
<
For high pressure
>
Ideal for applications such as
checking reference pressure.
Can also be used for simple
suction.
Ideal for applications such
as suction.
No mis-operations due to
vacuum breakdown occur.
Resolution: 1/2,000
Response time: 2.5 ms
Temperature characteristics
: ±0.5 % F.S.
Repeatability: ±0.1 % F.S.
Displays measurements in 0.1 kPa
Sensors can be connected to a master sensor one by one, and a copy of the setting details for the master sensor can be transmitted as data to the other
sensors. If making the same settings for multiple sensors, this prevents setting errors from occurring with the other sensors and also reduces the number
of changes required to instruction manuals when equipment designs are changed.
Copy function reduces man-hours and human error
Copying via wiring
+V
0 V
Comparative output 1
Comparative output 2
+V
0 V
Comparative output 1
Comparative output 2
Power supply
Slave sensorMaster sensor
Details copied
Details transmitted
Details received
The setting levels are clearly separated into “RUN mode”
for operation settings that are carried out daily, “MENU
SETTING mode” for basic settings, and “PRO mode”
for special and detailed setting. These make setting
operations easy to understand and easy to carry out.
The sensor’s setting operation mode has a 3-level conguration to suit the frequency of use
Simple setting
Settings such as threshold value
adjustment and key lock operation
can be carried out while the sensor
is operating.
Basic settings such as output mode
setting and NO / NC switching can
be carried out.
MENU SETTING mode
RUN mode
High-level function settings such as
hysteresis adjustment and the copy
function can be carried out.
PRO mode
RUN mode
PRO mode
MENU SETTING mode
Special and
detailed setting