Datasheet

Dual Display Digital Pressure Sensor DP-100 SERIES
676
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Other
Products
DP-100
DP-M
ZD1
D1
D2
(White) Analog voltage output
or External input
Load
(Black)
Comparative output 1
Tr1
Tr2
100 mA max.
1
4
2
3
Userscircuit Internal circuit
12 to 24 V DC
±10 %
+
(Brown) +V
(Blue) 0 V
Sensor circuit
Terminal No.
Color code of connection cable
1kΩ
12 to 24 V DC
±10 %
+
(Black) Comparative output 1
Load
Load
(White) Comparative output 2
Tr1
ZD2
ZD1
Tr2
100 mA max.
100 mA max.
(Blue) 0 V
D
1
4
2
3
Userscircuit Internal circuit
Sensor circuit
Terminal No.
Color code of connection cable
(Brown) +V
I/O circuit diagram Terminal arrangement diagram
Terminal
No.
Designation
1
+V
2
Standard type: Comparative output 2
Multi-functiontype:AnalogvoltageoutputorExternalinput
3
0 V
4
Comparative output 1
Standard type
Multi-function type
Symbols … D: Reverse supply polarity protection diode
Z
D1,
Z
D1
: Surge absorption zener diode
Tr
1
, Tr
2
: PNP output transistor
Mounting
•The MS-DP1-1 sensor mounting bracket is available
separately, and it should be used for mounting. When
tightening the sensor to the sensor mounting bracket, use
a tightening torque of 0.5 N·m or less.
Sensor mounting bracket
MS-DP1-1 (Optional)
M3 (length 6 mm 0.236 in)
screws with washers
(Accessory for
MS-DP1-1
)
•The MS-DP1-2 panel mounting bracket (optional) and
the MS-DP1-3 front protection cover (optional) are also
available.
Front protection cover
MS-DP1-3
(optional)
Panel mounting bracket
MS-DP1-2
(optional)
Connection
Connector
attached cable
[CN-14A(-R)-C□]
•Do not apply stress directly to
the connection cable leader or
to the connector.
Conditions in use for CE conformity
•The DP-100 series is a CE conformity product complying
with EMC Directive. The harmonized standard with regard
to immunity that applies to this product is EN 61000-6-2
and the following condition must be met to conform to that
standard.
Conditions
•The line to connect with this sensor should be less than
30 m 98.425 ft.
PRECAUTIONS FOR PROPER USE
Refer to General precautions.
I/O CIRCUIT AND WIRING DIAGRAMS
1
2
3
4
Symbols … D
1
, D
2
: Reverse supply polarity protection diode
Z
D1
: Surge absorption zener diode
Tr
1
: PNP output transistor
Tr
2
: NPN input transistor
DP-11-E-P-J
PNP output type
•Never use this product as a sensing device
for personnel protection.
•In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
•The DP-100 series is designed for use with
non-corrosive gas. It cannot be used with
liquid or corrosive gas.