Data Sheet

Dimensions
(with tube)
Typical charge characteristics
Specifications
Typical discharge characteristics
*1 After charging at 0.1 It for 16 hours, discharging at 0.2 It
*2 For reference only.
*3 Need specially designed control system. Please contact Panasonic for details.
Battery performance and cycle life are strongly affected by how they are used. In order
to maximize battery safety, please consult Panasonic when determining charge/discharge
specs, warning label contents and unit design.
0.8
0.9
1.0
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
0 1 2 3 4 5 6
Voltage / V
Discharge time / hours
-20℃
20℃
0
10
20
30
40
50
60
70
80
90
100
110
120
-30 -20 -10 0 10 20 30 40 50 60 70 80
Capacity Ratio / %
Temperature /
0.8
0.9
1.0
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
2.0
0 2 4 6 8 10 12 14 16 18
Voltage / V
Charge time / hours
-20℃
20℃
75℃
BK1100FHU
New
F size
Unit : mm
2017/11
φ33.0+0/-1.0
91.0+0/-2.5
Charge : 1100 mA (0.1It) X 16hrs.
Charge : 1100 mA (0.1It) X 16hrs.
Charge temperature : -20 to 75
Discharge : 11000 mA (1It)
Cut off voltage : 1.0V
Discharge tenperature : 20
Charge : 5500 mA, -dV=5mV
Charge temperature : 20
Discharge : 2200 mA (0.2It)
Cut off voltage : 1.0V
Discharge tenperature : -20 to 75