Datasheet
16
OUTPUT CIRCUIT
Wiring diagram
CONTACTS
1) Screw terminal type
Internal circuit
2) LED wired type
Lamp lighting circuit
Note: Since LED is connected to N.O. side,
the polarity of the load shall be + for N.O.
Screw terminal type
Plunger type Lever type
Connector type
Contact No.
1
2
3
4
Terminals
Color of lead-
wire
— Brown
N.C. White
COM Blue
N.O. Black
Rating
24 V DC
Leakage
current
Internal
resistance
1.5 mA
18 kΩ
IEC standard
IP64
Die cast
case
Plastic case
❍❍
IP67
❍
×
LED rating Protective construction
The leakage current changes depends on the resis-
tance of load connected in parallel.
12
N.C.
14
N.O.
11
COM
2
N.C.
4
N.O.
LED
resistance
3
COM
N.O.
COM N.C.
The terminal cover
can be mounted in
both directions.
N.C.
COM N.O.
The terminal cover
can be mounted in
both directions.
1
4
3
2
4. Performance data for EN60947-5-1
250V AC 250V AC 30V DC 30V DC
Item
Rated insulated voltage
Plastic case
Standard
Plastic case
Bifurcated
Die casting case
Standard
Die casting case
Bifurcated
2.5kV 2.5kV 1.5kV 1.5kVImpulse withstand voltage
2.5kV 0.8kV 0.8kV 0.8kVSwitching excess voltage
5A 1A 5A 1A
Rated closed thermocurrent
100A 100A 100A 100A
Conditional short-circuit current
10A Fuse
3
10A Fuse
3
10A Fuse
3
10A Fuse
3
Short-circuit protection
Degree of contamination
IP64 (switch)
IP54 (terminal)
IP64 (switch)
IP54 (terminal)
IP67 IP67
Protective construction
HL (AZH)
04/2005