Datasheet
Turquoise Stroke Switches (ASQ1)
–3–
AECTB6E 201701-T
■ Protection grade
■ Operating characteristics
Notes: 1. The above indicates the characteristics when operating the pushbutton from the vertical direction.
2. Indicates operation load for NO contact to achieve ON status.
3. Indicates position for NC contact to achieve OFF status.
4. Indicates position for NO contact to achieve ON status.
5. Indicates position for NC contact to achieve ON status.
6. Indicates position for NO contact to achieve OFF status.
OPERATION CONCEPT DIAGRAM
DATA
Applicable current range (Reference)
Characteristics Unit Pin plunger Leaf lever Simulated leaf lever
Operating Force (max. OF) *
Note 2
N 1.5 1.7 1.5
Total travel Force (max. TF) (reference value) N (2.0) (3.1) (2.8)
Free Position (max. FP)
From mounting boss and hole center line
mm
9.2 11.5 14.4
From standoff 13.4 15.7 18.6
Operating Position on NC side
OP (NC) *
Note 3
From mounting boss and hole center line
mm
8.7±0.3 9.8±0.5 12.5±0.5
From standoff 12.9±0.3 14.0±0.5 16.7±0.5
Operating Position on NO side
OP (NO) *
Note 4
From mounting boss and hole center line
mm
8.4±0.3 9.3±0.5 12.0±0.5
From standoff 12.6±0.3 13.5±0.5 16.2±0.5
Release Position on NC side
RP (NC) *
Note 5
From mounting boss and hole center line
mm
8.8±0.3 10.1±0.5 12.9±0.5
From standoff 13.0±0.3 14.3±0.5 17.1±0.5
Release Position on NO side
RP (NO) *
Note 6
From mounting boss and hole center line
mm
8.5±0.3 9.6±0.5 12.4±0.5
From standoff 12.7±0.3 13.8±0.5 16.6±0.5
Over travel on NC side (min. OT (NC)) mm 2.5 3.1 3.3
Over travel on NO side (min. OT (NO)) mm 2.2 2.6 2.8
Total Travel Position (TTP)
(reference value)
From mounting boss and hole center line
mm
(5.9) (6.2) (8.7)
From standoff (10.1) (10.4) (12.9)
1) JIS C0920 (water-resistance experiments for electrical
machines and protection rating against incursion of solid
substances): Immersion protected (Note 1)
2) IEC 60529 (rating for outer shell protection): IP67 (Immersion
protected) (Note 1)
3) JIS D0203 (method for testing moisture resistance and water
resistance in automotive components): Equivalent of D2 (Note 2)
Note 1) A concrete testing method is to check for any adverse effect on the structure
after leaving it submerged for 30 minutes under 1 m of water (with
temperature difference between water and switch no larger than 5°C).
Note 2) A concrete testing method is to check for any adverse effect on the structure
after leaving it submerged for 10 minutes under 10 cm water (with
temperature difference between water and switch no larger than 30°C).
Contact form: SPDT
TF
RF
OF
Stroke
Operation load
Contact force
Range of possible use
Operation
load
NC side
NO side
RP (NC)
OP (NC)
OT (NC)
OT (NO)
TTP
OP (NO)
FP
RP (NO)
Standard (mounting boss and
hole center diameter or standoff)
0
NC side
NO side
0
(OFF)
Applicable range
100mA
1mA
0
30V5VDC