Datasheet

Turquoise Stroke Switches (ASQ1)
–4–
AECTB6E 201701-T
DIMENSIONS
Terminal type: Mounting hole 3 mm, standard type Pin plunger
Terminal type: Leaf lever
(Unit: mm) General tolerance: ±0.25
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
External dimensions
1.9 dia.
FP 13.4 MAX.
OP (NC) 12.9±0.3
RP (NC) 13.0±0.3
OP (NO) 12.6±0.3
RP (NO) 12.7±0.3
TTP (10.1)
FP 9.2 MAX.
OP (NC) 8.7±0.3
RP (NC) 8.8±0.3
OP (NO) 8.4±0.3
RP (NO) 8.5±0.3
TTP (5.9)
1.2
8.4±0.2
2.0
5.4±0.15
5.4
0.4
4.53±0.15
2.7
4.53±0.15
3.2±0.1
4.1
13.3±0.15
C0.3
0.4
1.5
3.0
+0.1
–0
3.0
+0
–0.1
dia.
8.3±0.1
3.7
4.2
5.9
5.1
3.0
+0.3
–0.2
Operating Force (max. OF) 1.5N
Free
Position
(max. FP)
From mounting boss
and hole center line
9.2mm
From standoff 13.4mm
Operating
Position on
NC side
OP (NC)
From mounting boss
and hole center line
8.7±0.3mm
From standoff 12.9±0.3mm
Operating
Position on
NO side
OP (NO)
From mounting boss
and hole center line
8.4±0.3mm
From standoff 12.6±0.3mm
Release
Position on
NC side
RP (NC)
From mounting boss
and hole center line
8.8±0.3mm
From standoff 13.0±0.3mm
Release
Position on
NO side
RP (NO)
From mounting boss
and hole center line
8.5±0.3mm
From standoff 12.7±0.3mm
Over travel on NC side
(min. OT (NC))
2.5mm
Over travel on NO side
(min. OT (NO))
2.2mm
CAD Data
External dimensions
Note: When switching at high speed or under shock, lever endurance may drop. Therefore,
please be sure to conduct an endurance evaluation under actual switching conditions.
1.9 dia.
FP 15.7 MAX.
FP 11.5 MAX.
14.0
(18°)
TTP (10.4)
3.3
OP (NO) 9.3±0.5
RP (NO) 9.6±0.5
OP (NC) 9.8±0.5
RP (NC) 10.1±0.5
OP (NC) 14.0±0.5
RP (NC) 14.3±0.5
OP (NO) 13.5±0.5
RP (NO) 13.8±0.5
TTP (6.2)
0.5
R1.2
C0.3
1.2
8.4±0.2
2.0
5.4±0.15
5.4
0.4
4.53±0.15
2.7
4.53±0.15
4.1
13.3±0.15
3.0
+0.3
–0.2
3.0
+0.1
–0
4.2
3.7
5.9
5.1
1.2
0.4
1.5
3.0
+0
–0.1
dia.
8.3±0.1
3.2±0.1
0.2
Operating Force (max. OF) 1.7N
Free
Position
(max. FP)
From mounting boss
and hole center line
11.5mm
From standoff 15.7mm
Operating
Position on
NC side
OP (NC)
From mounting boss
and hole center line
9.8±0.5mm
From standoff 14.0±0.5mm
Operating
Position on
NO side
OP (NO)
From mounting boss
and hole center line
9.3±0.5mm
From standoff 13.5±0.5mm
Release
Position on
NC side
RP (NC)
From mounting boss
and hole center line
10.1±0.5mm
From standoff 14.3±0.5mm
Release
Position on
NO side
RP (NO)
From mounting boss
and hole center line
9.6±0.5mm
From standoff 13.8±0.5mm
Over travel on NC side
(min. OT (NC))
3.1mm
Over travel on NO side
(min. OT (NO))
2.6mm
CAD Data