Datasheet

RD (ARD)
–6–
ASCTB103E 201411-T
2) SP6T
Notes: *1 Factors such as heating of the connected connector influence the high frequency characteristics; therefore, please verify under actual conditions of use.
*2 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to “AMBIENT ENVIRONMENT”
in GENERAL APPLICATION GUIDELINES.
Characteristics Item Specifications
Contact
Arrangement SP6T
Contact material Gold plating
Initial contact resistance Max. 100mΩ (By voltage drop 6V DC 1A)
Rating
Contact
input power
No termination 120 W (at 3GHz) (V.S.W.R. 1.15 or less, no contact switching, ambient temperature 25°C 77°F)*
1
With termination 2W (at 3GHz) (V.S.W.R. 1.15 or less, no contact switching, ambient temperature 25°C 77°F)*
1
Nominal
operating
power
Fail-safe 840mW (4.5V, 12V DC), 930mW (24V DC)
Latching 600mW (4.5V DC), 600mW (12V DC), 620mW (24V DC)
Indicator rating
Contact rating Max. 30V 100mA
Initial contact resistance Max. 1Ω (Measured by 5V 100mA)
Min. switching capacity
(Reference value)
3V DC, 0.1mA (5 × 10
6
, Reliability level: 10% (3kΩ))
High frequency
characteristics
(Impedance 50Ω)
to 1 GHz 1 to 4 GHz 4 to 8 GHz 8 to 12.4 GHz 12.4 to 18 GHz
V.S.W.R.
(max.)
No termination 1.1 1.15 1.25 1.35 1.50
With termination 1.20 1.40 1.50 1.50
Insertion loss (dB, max.) 0.2 0.3 0.4 1.0
Isolation (dB, min.) 85 80 70 65 60
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000 MΩ (at 500 V DC) Measurement at same location as “breakdown voltage (Initial)” section.
Breakdown
voltage
(Initial)
Between open
contacts
500 Vrms for 1 min. (Detection current: 10mA)
Between contact
and coil
500 Vrms for 1 min. (Detection current: 10mA)
Between contact
and earth terminal
500 Vrms for 1 min. (Detection current: 10mA)
Between coil and
earth terminal
500 Vrms for 1 min. (Detection current: 10mA)
Time characteristics
(at 20°C 68°F)
Operate time Max. 20ms (Nominal operating voltage applied to the coil, excluding contact bounce time.)
Mechanical
characteristics
Shock
resistance
Functional Min. 500 m/s
2
(Half-wave pulse of sine wave: 11ms, detection time: 10μs.)
Destructive Min. 1,000 m/s
2
(Half-wave pulse of sine wave: 11ms.)
Vibration
resistance
Functional 10 to 55 Hz at double amplitude of 3mm (Detection time: 10μs.)
Destructive 10 to 55 Hz at double amplitude of 5mm
Expected life
Mechanical Min. 5 × 10
6
(at 180 cpm)
Electrical
High frequency
contact (Hot switch)
No termination Min. 5 × 10
6
(5W to 3GHz, impedance 50Ω, V.S.W.R.; max. 1.2) (at 20 cpm)
With termination Min. 5 × 10
6
(2W to 3GHz, impedance 50Ω, V.S.W.R.; max. 1.2) (at 20 cpm)
Indicator (with
indicator type only)
5 VDC, 10 mA, Min. 10
6
(at 20 cpm)
Conditions
Conditions for operation,
transport and storage*
2
Ambient temperature: –55°C to +85°C –67°F to +185°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Unit weight Approx. 320g 11.29oz