Datasheet
GU 2 Form A (AQW21)
2
ds_x615_en_aqw21: 011212J
2. Electrical characteristics (Ambient temperature: 25C 77F)
*Turn on/Turn off time
RECOMMENDED OPERATING CONDITIONS
Please obey the following conditions to ensure proper relay operation and resetting.
Dimensions
Schematic and Wiring Diagrams
Cautions for Use
■ These products are not designed for automotive use.
If you are considering to use these products for automotive applications, please contact your local Panasonic technical
representative.
Please refer to our information on PhotoMOS Relays for Automotive Applications.
REFERENCE DATA
Item Symbol AQW212(A) AQW215(A) AQW217(A) AQW210(A) AQW214(A) AQW216(A) Condition
Input
LED operate
current
Typical
I
Fon
0.9 mA
IL = Max.
Maximum 3 mA
LED turn off
current
Minimum
I
Foff
0.4 mA
IL = Max.
Typical 0.8 mA
LED dropout
voltage
Typical
V
F
1.25 V (1.14 V at IF = 5 mA)
IF = 50 mA
Maximum 1.5 V
Output
On resistance
Typical
R
on
0.83 2.3 11 23 30 70
I
F = 5 mA
I
L = Max.
Within 1 son time
Maximum 2.5 4.0 15 35 50 120
Off state leakage
current
Maximum I
Leak 1 A
I
F = 0 mA
V
L = Max.
Transfer
characteristics
Turn on time*
Typical
Ton
0.65 ms 0.60 ms 0.25 ms 0.25 ms 0.31 ms 0.28 ms
I
F = 5 mA
I
L = Max.
Maximum 2 ms 2 ms 1.0 ms 0.5 ms 0.5 ms 0.5 ms
Turn off time*
Typical
T
off
0.08 ms 0.06 ms 0.05 ms 0.05 ms 0.05 ms 0.04 ms
I
F = 5 mA
I
L = Max.
Maximum 0.2 ms
I/O capacitance
Typical
C
iso
0.8 pF
f = 1 MHz
V
B = 0 V
Maximum 1.5 pF
Initial I/C isolation
resistance
Minimum R
iso 1,000 M 500 V DC
Item Symbol Recommended value Unit
Input LED current IF 5mA
To n
Input
Output 10%
90%
To f f
1. Load current vs. ambient temperature
characteristics
Allowable ambient temperature: –40C to +85C
–40F to +185F
2-(1) On resistance vs. ambient temperature
characteristics
Measured portion: between terminals 5 and 6, 7 and 8;
LED current: 5 mA; Load voltage: Max. (DC);
Continuous load current: Max. (DC)
2.-(2) On resistance vs. ambient temperature
characteristics
Measured portion: between terminals 5 and 6, 7 and 8;
LED current: 5 mA; Load voltage: Max. (DC);
Continuous load current: Max. (DC)
Load current, mA
0
200
300
600
500
400
0204060
80
85
100–40 –20
100
Ambient temperature, °C
AQW212
AQW215
AQW217
AQW210
AQW216
AQW214
0
1
2
3
4
–40
5
0–20 20 40 60 8085
AQW212
AQW215
On resistance, Ω
Ambient temperature, °C
0
20
40
60
80
–40
120
0–20 20 40 60 8085
100
AQW210
AQW217
AQW214
On resistance, Ω
Ambient temperature, °C
AQW216