Datasheet
AQ1
2
ds_61601_0001_en_aq1: 060207D
ORDERING INFORMATION
SPECIFICATIONS
1. Rating (at 20°C 68°F, Ripple factor: less than 1%)
Notes: *1 When heat sink (AQ-HS-5A) is installed. The max. load current is 5 A when heat sink is not installed.
*2 When heat sink (AQ-HS-5A) is installed. The max. load current is 3 A when heat sink is not installed.
*3 When load current is below the rating, refer to “Cautions for Use”.
2. Characteristics (at 20°C 68°F, Ripple factor: less than 1%)
Type
Item
AC output type
DC output type
RemarksZero-cross
3 A type 10 A type 2 A type 5 A type 1 A type 2 A type
Input
side
Input voltage 4 to 32 V DC 3 to 28 V DC 3 to 28 V DC
Input impedance —
Approx. 1.6 kΩ
(3 to 28 V DC)
Approx. 1.6 kΩ
(3 to 28 V DC)
Input current, max. 20 mA — —
Drop-out voltage, min. 1.0 V 0.8 V 0.8 V
Load
side
Max. load current 3 A 10 A*
1
2 A 5 A*
2
1 A 2 A Refer to “REFERENCE DATA
1. Load current vs. ambient
temperature characteristics”.
Load voltage 75 to 250 V AC 10 to 200 V DC 3 to 60 V DC
Non-repetitive surge
current
100 A 80 A 100 A 5 A (1 s)
AC: In one cycle at 60 Hz,
DC: 1s
Max. “OFF-state”
leakage current
5 mA 1 mA
AC: at 200 V, 60Hz
DC: When maximum load
voltage is applied.
Max. “ON-state”
voltage drop
1.6 V 1.6 V 2.3 V At Max. carrying current
Min. load current 50 mA*
3
5 mA*
3
Type
Item
AC output
DC output RemarksZero-cross
3 A type 10 A type 2 A type 5 A type
Operate time, Max. (1/2 cycle of voltage sine wave) + 1 ms 0.5 ms
Release time, Max. (1/2 cycle of voltage sine wave) + 1 ms 2 ms
Insulation resistance, Min. 100 M Ω for input, output and case
100 M Ω for input,
output
at 500 V DC
Breakdown voltage
4,000 Vrms
between input and output
2,500 Vrms
among input, output and case
3,000 Vrms
between input
and output
3,000 Vrms
between input
and output
1,500 Vrms
among input,
output and case
3,000 Vrms between
input-output
For 1 minute
Vibration
resistance
Destructive 117.6 m/s
2
{12G}, 10 to 55 Hz at double amplitude of 2 mm
117.6 m/s
2
{12G},
10 to 55 Hz at double
amplitude of 2 mm
1 hour for
X, Y, Z axis
Functional 117.6 m/s
2
{12G}, 10 to 55 Hz at double amplitude of 2 mm
117.6 m/s
2
{12G},
10 to 55 Hz at double
amplitude of 2 mm
10 minutes for
X, Y, Z axis
Shock
resistance
Destructive Min. 980 m/s
2
{100 G} Min. 980 m/s
2
{100 G}
5 times each for
X, Y, Z axis
Functional Min. 980 m/s
2
{100 G} Min. 980 m/s
2
{100 G}
4 times each for
X, Y, Z axis
Ambient temperature –30°C to +80°C –22°F to +176°F
Storage temperature –30°C to +100°C –22°F to +212°F
Operational method Zero-cross (Turn-ON and Turn-OFF) —
2A 2 J ZP 3/28 VDCAQ
Load current
1 A
2 A
3 A
5 A
10 A
Load voltage
2:
D1:
D2:
75 to 250 V AC
03 to 60 V DC
10 to 200 V DC
Shape
Nil:
J:
Vertical type
Flat type
Type
Nil:
ZP:
ZT:
T:
DC output
Zero-cross AC output (Photocoupler)
Zero-cross AC output (Phototriac coupler)
Non zero-cross AC output (Phototriac coupler)
Input voltage
3/28 V DC: 3 to 28 V DC