1. Ratings (Measurement condition: at 20°C 68°F, Input ripple: 1% or less)
Note: * When the load current is less than the rated minimum load current, please refer to “Cautions for Use”.
2. Characteristics (Measurement condition: at 20°C 68°F, Input ripple: 1% or less)
REFERENCE DATA
1. Load current vs. ambient temperature
Use load current within range specified in the figure below.
Tested condition
Part No.
Item
AQA211VL AQA411VL AQA611VL Remarks
Input side
Control voltage 4 to 32 V DC
Input current Max. 20 mA
Drop-out voltage Min. 1 V
Output side
Max. load current 15 A 25 A 40 A
Load voltage 75 to 250 Vrms
Frequency 45 to 65 Hz
Non-repetitive surge current 150 A 250 A 400 A In one cycle at 60 Hz
“OFF-state” leakage current Max. 10 mA at 60 Hz
“ON-state” voltage drop Max. 1.6 V at Max. carrying current
Min. load current* 100 mA
Part No.
Item
AQA211VL AQA411VL AQA611VL Remarks
Operate time Max. 1/2 cycle of voltage sine wave +1 ms
Release time Max. 1/2 cycle of voltage sine wave +1 ms
Insulation resistance Min. 100 MΩ between input and output at 500 V DC
Breakdown voltage
4,000 Vrms between input and output
2,500 Vrms between input, output and case
for 1 minute
Vibration resistance (Functional) 10 to 55 Hz double amplitude of 1.5 mm X, Y, Z axes
Shock resistance (Functional) Min. 980 m/s
2
X, Y, Z axes
Ambient temperature –20 to +80°C –4 to +176°F Non-condensing at low temperatures
Storage temperature –20 to +85°C –4 to +185°F Non-condensing at low temperatures
Operational method Zero-cross (Turn ON and Turn OFF)
With external heat sink
When using standard heat sink (AQP-HS-J25A,
AQP-HS-30/40A, AQP-HS-J10A, AQP-HS-SJ20A)
1) If attached to a heat sink, use a heat conductive
compound (Ex. Momentive Performance Materials
Inc. YG6111 or TSK5303) of similar coating to
improve cooling.
Without external heat sink
If the mounting surface is not metallic and a heat sink
is not used, expose the bottom surface and plate
surface to improve heat dissipation.
(1) 15 A type (AQA211VL) (2) 25 A type (AQA411VL)
5
10
15
20
0
0-20 20 40 60 80 100
Ambient temperature, °C
Load current, A
When using AQP-HS-J10A or
AQP-HS-SJ20A
When using as stand-alone
Ambient temperature, °C
Load current, A
When using as stand-alone
10
5
15
25
20
30
0
0-20 20 40 60 80 100
When using
AQP-HS-30/40A
When using
AQP-HS-J10A
When using
AQP-HS-SJ20A
(3) 40 A type (AQA611VL) 2. Non-repetitive surge current vs. carrying
time characteristics*
3. Input current vs. input voltage characteristics
Ambient temperature, °C
Load current, A
When using as stand-alone
10
20
40
30
50
0
0-20 20 40 60 80 100
When using
AQP-HS-30/40A
When using
AQP-HS-J10A
When using
AQP-HS-J25A
When using
AQP-HS-SJ20A
100
200
400
300
500
0
1 10 100
AQA211VL AQA411VL AQA611VL
No. of cycles at 60 Hz
Non-repetitive surge current, A
4
8
16
12
20
0
0 1015202530535
Input voltage, V
Input current, mA
Note: * The above chart shows non-repetitive maximum rating. If a surge current is applied repeatedly, please keep it approximately 50% or less than the values shown in
the above graph.