Datasheet

PF (APF)
4
ds_61C16_en_pf: 070313D
DIMENSIONS (mm inch)
SAFETY STANDARDS
NOTES
For Cautions for Use, see Relay Technical Information.
Certification
authority
File No. Applicable standard Rating Remarks
UL, C-UL E120782
UL508, CSA C22.2 No.14
UL1604 (class I, Division 2, Group A, B, C, D)
277V AC 8A, General use,
24V DC 6A, General use,
B300, R300 (Pilot Duty)
VDE 40027672 EN/IEC 61810-1
250V AC 6A (cos = 1.0) 85C 185F
N.O. side, N.C. side
250V AC 8A (cos = 1.0) 25C 77F
N.O. side
Insulation: Reinforced insulation between contact
and coil.
Resistance to heat and fire; EN60335-1, clause
30 (GWT) approved.
Download from our Web site.
CAD Data
CAD Data
1. 1 Form A type
CAD Data
External dimensions
General tolerance: 0.3 .012
0.4
.016
1.2
.047
3.78
.149
2-0.6
2-.024
28.0max.
1.102max.
21.42
.843
2-1.0
2-.039
5.04
.198
1.9
.075
0.5
.020
15.0max.
.591max.
3.5±0.5
.138±.020
5.0max.
.197max.
1.2
.047
0.48
.019
PC board pattern (Bottom view)
Tolerance: 0.1 .004
Schematic (Bottom view)
3.78
.149
21.42
.843
5.04
.198
1.9
.075
1.2
.047
2-1.0 dia.
2-.039 dia.
2-1.3 dia.
2-.051 dia.
NO
COM
COIL
2. 1 Form C type
CAD Data
External dimensions
General tolerance: 0.3 .012
0.4
.016
1.2
.047
2-0.6
2-.024
21.42
.843
3-1.0
3-.039
0.5
.020
3.5±0.5
.138±.020
5.0max.
.197max.
1.2
.047
0.48
.019
3.78
.149
1.9
.075
28.0max.
1.102max.
5.04
.198
5.04
.198
15.0max.
.591max.
PC board pattern (Bottom view)
Tolerance: 0.1 .004
Schematic (Bottom view)
3.78
.149
21.42
.843
5.04
.198
5.04
.198
1.9
.075
1.2
.047
2-1.0 dia.
2-.039 dia.
3-1.3 dia.
3-.051 dia.
NO
COM
NC
COIL
Usage, transport and storage
conditions
1) Temperature:
–40 to +85C –40 to +185F
2) Humidity: 5 to 85% RH
(Avoid freezing and condensation.)
The humidity range varies with the
temperature. Use within the range
indicated in the graph below.
3) Atmospheric pressure: 86 to 106 kPa
Temperature and humidity range for
usage, transport, and storage
4) Condensation
Condensation forms when there is a
sudden change in temperature under
high temperature and high humidity
conditions. Condensation will cause
deterioration of the relay insulation.
5) Freezing
Condensation or other moisture may
freeze on the relay when the
temperatures is lower than 0C 32F.
This causes problems such as sticking of
movable parts or operational time lags.
6) Low temperature, low humidity
environments
The plastic becomes brittle if the relay is
exposed to a low temperature, low
humidity environment for long periods of
time.
85
5
Humidity, %RH
Tolerance range
(Avoid
condensation
when used at
temperatures
higher than
0°C 32°F)
(Avoid freezing
when used at
temperatures
lower than
0°C 32°F)
850-40
+185+32-40
Temperature, °C °F