Datasheet

PF (APF)
2. Specifications
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981
*3. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to “Usage, transport and storage
conditions” in NOTES.
*4. For cycle lifetime, refer to “Cautions for use 4)” in NOTES.
REFERENCE DATA
1. Electrical life
Tested sample: APF30224
Notes: 1. Switch contacts are all on N.O. side.
2. AC 15 and DC 13 comply with IEC-60947-5-1 testing conditions.
Characteristic Item Specifications
Contact
Arrangement 1 Form A 1 Form C
Contact resistance (Initial) Max. 100 m (By voltage drop 6 V DC 1A)
Contact material AgNi type, AgNi type/Au-plated
Rating
Nominal switching capacity (resistive load) 6 A 250 V AC
Max. switching power (resistive load) 1,500 VA
Max. switching voltage 250V AC
Max. switching current 6 A (AC)
Nominal operating power 170 mW (5 to 24 V DC), 217 mW (48 V DC), 175 mW (60 V DC)
Min. switching capacity (Reference value)*
1
100 mA 5 V DC (without Au-plated), 1 mA 1 V DC (with Au-plated)
Electrical
characteristics
Insulation resistance (Initial)
Min. 1,000M (at 500V DC)
Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 4,000 Vrms for 1 min. (Detection current: 10 mA)
Surge breakdown voltage*
2
(Between contact and coil) (Initial)
6,000 V
Temperature rise (coil) (at 20°C 68°F)
Max. 45°C 113°F
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 6A.)
Operate time (at 20°C 68°F)
Max. 8 ms
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
Release time (at 20°C 68°F)
Max. 4 ms
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Mechanical
characteristics
Shock resistance
Functional
Min. 98 m/s
2
(Half-wave pulse of sine wave: 11 ms;
detection time: 10µs)
Min. 49 m/s
2
(Half-wave pulse of sine wave: 11 ms;
detection time: 10µs)
Destructive Min. 980 m/s
2
(Half-wave pulse of sine wave: 11 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 1 mm (Detection time: 10µs.)
Destructive 10 to 55 Hz at double amplitude of 1.5 mm
Expected life
Mechanical Min. 5×10
6
(at 180 times/min.)
Electrical*
4
N.O.: Min. 5×10
4
(at resistive load, 6 times/min. and
nominal switching capacity)
N.O.: Min. 5×10
4
, N.C.: Min. 3×10
4
(at resistive load, 6 times/min. and
nominal switching capacity)
Conditions Conditions for operation, transport and storage*
3
Ambient temperature: –40°C to +85°C –40°F to +185°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Unit weight Approx. 5 g .18 oz
Load type Voltage Current Ambient temperature No. of ops.
Resistive load 250V AC 6 A 85°C 185°F 30,000
Inductive load
AC 15 250V AC 3 A 25°C 77°F 20,000
DC 13 24V DC 2 A 25°C 77°F 6,000
2. Max. switching capacity (AC) 3. Coil temperature rise
Tested sample: APF30224
Measured portion: Inside the coil
Ambient temperature: 28°C 82°F
4. Ambient temperature characteristics
Tested sample: APF30224, 6 pcs.
1
0.5
0.2
0.3
0.4
2
3
4
5
6
10
10 20 30 50 100 250
Contact voltage, V
Contact current, A
6A
0A
50
60
70
80
90
40
30
20
10
0
10090 110 120 140130
Coil applied voltage, %V
Te mperature rise, °C
5
10
-20
-40 -20
0
0
20
8560
40
-15
-10
-5
15
20
Pick-up voltage
Drop-out
voltage
Ambient
temperature,
°C
Rate of
change, %
All Rights Reserved © C