Datasheet

PIR Motion Sensor (EKMB, EKMC, AMN2, 3)
3
ds_61802_en_pir_motion_sensor: 190813D
2) NaPiOn series
a) Digital output
Note: The current which is consumed during detection consists of the standby consumed current plus the output current.
b) Analog output
Note: To set the same detection performance as the digital output type, set the output voltage (2.5V) 0.45V.
3. Detection performance
1) WL series VZ series
2) NaPiOn series
Items Symbol Specified value Measuring conditions
Rated consumption current
(Stand by) Note)
Iw 170A ave.
Ambient temperature = 25C 77F
Operating voltage = 5V
Iout = 0
Rated operating voltage Vdd
3.0VDC min.
6.0VDC max.
Output current (When detecting) Iout 100uA
Ambient temperature = 25C 77F
Operating voltage = 5V
Vout Vdd-0.5V
Output voltage (When detecting) Vout Vdd-0.5V
Ambient temperature = 25C 77F
Operating voltage = 5V
Open when not detecting
Circuit stability time Twu 30s max.
Ambient temperature = 25C 77F
Operating voltage = 5V
Items Symbol Specified value Measuring conditions
Consumption current Iw 170A ave.
Ambient temperature = 25C 77F
Operating voltage = 5V
Iout = 0
Operating voltage Vdd
4.5VDC min.
5.5VDC max.
Output current Iout 50A
Ambient temperature = 25C 77F
Operating voltage = 5V
Output voltage range Vout
0V min.
VDD max.
Ambient temperature = 25C 77F
Operating voltage = 5V
Output offset average voltage Voff
2.3V min.
2.5V ave.
2.7V max.
Ambient temperature = 25C 77F
Operating voltage = 5V
Steady-state output voltage when not detecting
Steady-state noise Vn
155mVpp ave.
300mVpp max.
Ambient temperature = 25C 77F
Operating voltage = 5V
Detection sensitivity Vh or Vl 0.45V
Ambient temperature = 25C 77
F
Operating voltage = 5V
Temperature difference with background: 4C 39.2F
Circuit stability time
Twu 45s
Ambient temperature = 25C 77F
Operating voltage = 5V
Items Standard type Long distance detection type Measuring conditions
Detection distance 5m 16.404ft 12m 39.3696ft
1. Detectable difference in temperature between the target
and background is more than 4C 7.2F.
2. Movement speed 1.0m/s
3. Detection object: human body
(size is 700mm 250mm 27.559inch 9.843inch)
Detection range
(Horizontal Vertical)
94 82 102 92
Detection zone 64 zones 92 zones
Items Standard type
Slight motion
detection type
Spot detection
type
10m detection
type
Measuring conditions
Detection distance 5m 16.404ft 2m 6.562ft 5m 16.404ft 10m 32.808ft
1. Detectable difference in temperature between the target
and background is more than 4C 7.2F.
2. Movement speed
1) Digital output type
Standard type/Spot type/10m detection type:
0.8 to 1.2m/s
Slight motion detection type: 0.5m/s
2) Analog output type
Standard type/Spot type/10m detection type:
0.5 to 1.5m/s
Slight motion detection type: 0.3 to 1.0m/s
3. Detection object: human body
(size is 700mm 250mm 27.559inch 9.843inch)
(for the slight motion detection type, 200mm 200mm
7.874inch 7.874inch)
Detection range
(Horizontal Vertical)
100 82 91 91 38 22 110 93
Detection zone
64 zones 104 zones 24 zones 80 zones