Datasheet

LQ (ALQ)
–3–
ASCTB92E 201603-T
3. Expected electrical life
Condition: Resistive load, at 20°C 68°F, at 20 times/min., with diode
REFERENCE DATA
Type Switching capacity No. of operations
1 Form A (at 20 times/min.)
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
5×10
4
5×10
4
10
5
1 Form C (at 20 times/min.)
N.O.
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
5×10
4
5×10
4
10
5
N.C.
3 A 125 V AC
2 A 250 V AC
1 A 30 V DC
2×10
5
2×10
5
10
5
1.-(1) Max. switching capacity (1 Form A type) 1.-(2) Max. switching capacity (1 Form C type) 2. Life curve (N.O. side)
Ambient temperature: room temperature
1,000
AC resistive load
10010 250
100
10
5
1
Contact voltage, V
Contact current, A
1,00025010010
100
10
5
3
2
1
Contact voltage, V
Contact current, A
AC resistive load N.O. side
AC resistive load N.C. side
125V AC resistive load
250V AC resistive load
1086420
100
10
1
Contact current, A
Life, ×10
4
3.-(1) Coil temperature rise (1 Form A type)
Measured portion: Inside the coil
Contact carrying current: 5 A, 10 A
3.-(2) Coil temperature rise (1 Form C type)
Measured portion: Inside the coil
Contact carrying current: 5 A, 10 A
4.-(1) Ambient temperature characteristics
(1 Form A type)
Contact carrying current: 5 A, 10 A
180160140120100
Coil applied voltage, %V
70
60
50
40
30
20
10
0
Temperature rise, °C
10 A at 70°C
5 A at 70°C
5 A at 85°C
10 A at 85°C
160150140130120110100
Coil applied voltage, %V
70
60
50
40
30
20
10
0
Temperature rise, °C
10 A at 70°C
10 A at 85°C
5 A at 85°C
5 A at 70°C
0 2030405060708090
Ambient temperature, °C
400
300
200
100
Coil applied voltage, %V
1
2
3
4
5
6
7
4.-(2) Ambient temperature characteristics
(1 Form C type)
Contact carrying current: 5 A, 10 A 1 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 5 A)
2 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 10 A)
3 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 5 A)
4 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 10 A)
5 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 10 A)
6 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 5 A)
7 Pick-up voltage
0 2030405060708090
Ambient temperature, °C
400
300
200
100
Coil applied voltage, %V
1
2
3
4
5
6
7