Datasheet
LF-G (ALFG)
2
ds_61B12_en_lfg: 050509J
TYPES
Standard packing: Carton: 50 pcs.; Case: 200 pcs.
RATING
Q Coil data
Q Specifications
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2 Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981
*3 In accordance with UL class-F
*4 Coil holding voltage is the coil voltage after 100 ms from the applied nominal coil voltage.
*5 The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to 1. Usage, transport and storage
conditions in NOTES.
Contact arrangement Nominal coil voltage
Part No.
Standard type High capacity type
1 Form A
9V DC ALFG1PF09 ALFG2PF09
12V DC ALFG1PF12 ALFG2PF12
18V DC ALFG1PF18 ALFG2PF18
24V DC ALFG1PF24 ALFG2PF24
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
(Initial)
Drop-out voltage
(at 20°C 68°F)
(Initial)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. allowable voltage
(at 20°C 68°F)
9V DC
70%V or less of
nominal voltage
10%V or more of
nominal voltage
115mA 58Ω
1,400mW
120%V of
nominal voltage
12V DC 117mA 103Ω
18V DC 78mA 230Ω
24V DC 59mA 410Ω
Characteristics Item
Specifications
Standard type High capacity type
Contact
Arrangement 1 Form A
Contact resistance (Initial) Max. 100 mΩ (By voltage drop 6 V DC 1A)
Contact material
AgSnO2 type
Rating
Nominal switching capacity 22A 250V AC 31A 250V AC
Max. switching power 5,500VA 7,750VA
Max. switching voltage 250V AC
Max. switching current 22A (AC) 31A (AC)
Nominal operating power 1,400mW
Min. switching capacity (Reference value)*
1
100mA 5V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 2,500 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 4,000 Vrms for 1 min. (Detection current: 10 mA)
Surge breakdown voltage*
2
(Between contact and coil)
6,000 V (initial)
Temperature rise*
3
Max. 95°C 203°F (By resistive method, nominal
coil voltage applied to the coil; contact carrying
current: 22A, at 60°C 140°F)
Max. 70°C 158°F (By resistive method, 80%V
of nominal coil voltage applied to the coil;
contact carrying current: 22A, at 85°C 185°F)
Max. 95°C 203°F (By resistive method, nominal
coil voltage applied to the coil; contact carrying
current: 31A, at 60°C 140°F)
Max. 70°C 158°F (By resistive method, 80%V
of nominal coil voltage applied to the coil;
contact carrying current: 31A, at 85°C 185°F)
Coil holding voltage*
4
35 to 120%V (contact carrying current: 22A,
at 20°C 68°F)
45 to 80%V (contact carrying current: 22A,
at 85°C 185°F)
35 to 120%V (contact carrying current: 31A,
at 20°C 68°F)
45 to 80%V (contact carrying current: 31A,
at 85°C 185°F)
Operate time (at 20°C 68°F) Max. 20 ms (at nominal coil voltage excluding contact bounce time.)
Release time (at 20°C 68°F) Max. 10 ms (at nominal coil voltage excluding contact bounce time, without diode)
Mechanical
characteristics
Shock resistance
Functional Min. 100 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
Destructive Min. 1,000 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10μs.)
Destructive 10 to 55 Hz at double amplitude of 1.5 mm
Expected life
Mechanical Min. 10
6
(at 180 cpm)
Electrical
Resistive load 22A 250V AC, Min. 3×10
4
(at 20 cpm) —
Inductive load
Destructive: 22A 250V AC (cosφ = 0.8),
Min. 3×10
4
(on:off = 0.1s:10s)
Over load: 35A 250V AC (cosφ = 0.8),
Min. 50 (on:off = 0.1s:10s)
Destructive: 31A 250V AC (cosφ = 0.8),
Min. 3×10
4
(on:off = 0.1s:10s)
Over load: 47A 250V AC (cosφ = 0.8),
Min. 50 (on:off = 0.1s:10s)
Conditions Conditions for operation, transport and storage*
5
Ambient temperature: –40°C to +60°C –40°F to +140°F (When nominal coil voltage applied)
–40°C to +85°C –40°F to +185°F (Coil holding voltage is when 45 to 80%V
of nominal coil voltage is applied.)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Air pressure: 86 to 106 kPa
Unit weight Approx. 23 g .81 oz