Datasheet

LE (ALE)
3
ds_61B11_en_le: 290212J
2. Specifications
* Specifications will vary with foreign standards certification ratings.
Notes:
*1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual
load.
*2. Wave is standard shock voltage of 1.250s according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport
Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
REFERENCE DATA
Characteristics Item Specifications
Contact
Contact material AgSnO2 type
Arrangement 1 Form A
Contact resistance (Initial) Max. 100 m (By voltage drop 6 V DC 1A)
Rating
Nominal switching capacity (resistive load) 16A 277V AC
Max. switching power (resistive load) 4,432VA
Max. switching voltage 277V AC
Max. switching current 16A
Nominal operating power 400mW (Standard type), 200mW (High sensitive type)
Min. switching capacity (reference value)*
1
100mA, 5V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000M (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 4,000 Vrms for 1 min. (Detection current: 10 mA)
Temperature rise (coil)
Max. 55C 131F, Max. 45C 113F (200mW type) (By resistive method, nominal coil voltage
applied to the coil; contact carrying current: 16A, at 20C 68F)
Surge breakdown voltage*
2
(Between contact and coil) (Initial)
10,000 V
Operate time (at nominal voltage) (at 20C 68F) Max. 20 ms (excluding contact bounce time.)
Release time (at nominal voltage) (at 20C 68F) Max. 20 ms, Max. 25 ms (200mW type) (excluding contact bounce time) (With diode)
Mechanical
characteristics
Shock resistance
Functional 200 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10s.)
Destructive 1,000 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10s.)
Destructive 10 to 55 Hz at double amplitude of 1.5 mm
Expected life
Mechanical (at 180 times/min.) Min. 210
6
Electrical (at 20 times/min.) Min. 10
5
(at resistive load)
Conditions
Conditions for operation, transport and storage*
3
Ambient temperature: –40C to +85C –40F to +185F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed 20 times/min. (at nominal switching capacity)
Unit weight Approx. 17 g .60 oz, Approx. 15 g .53 oz (PCB type)
1-1. Coil temperature rise (400mW type)
Sample: ALE14B12, 6 pcs.
Point measured: coil inside
Ambient temperature: 25C 77F, 85C 185F
1-2. Coil temperature rise (200mW type)
Sample: ALE74B12, 6 pcs.
Point measured: coil inside
Ambient temperature: 23.7C 74.66F, 85C 185F
2. Life curve
800
0
10
20
30
40
Temperature rise, °C
Coil applied voltage, %V
50
60
100 145
12A
12A
16A
0A
16A
0A
85°C
25°C
800
0
5
10
15
20
Temperature rise, °C
Coil applied voltage, %V
25
30
100 145
16A
0A
16A
0A
85°C
23.7°C
100
10
1
20 4 6 8 10 12 14 16
250V AC resistive load
Contact current, A
Life, x10
4