Datasheet
LA (ALA)
2
ds_61B09_en_la: 070313D
2. Specifications
Notes:
*1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual
load.
*2. Wave is standard shock voltage of 1.250s according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport
Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
REFERENCE DATA
Characteristics Item
Specifications
3A type 5A TV type (TV-4)
Contact
Arrangement 2 Form A
Contact resistance (Initial) Max. 50 m (By voltage drop 6V DC 1A) Max. 100 m (By voltage drop 6V DC 1A)
Contact material Gold-clad, AgNi type AgSnO2 type
Rating
Nominal switching capacity (resistive load) 3A 125V AC 5A 277V AC
Max. switching power (resistive load) 625VA 1,385VA
Max. switching voltage 125V AC 277V AC
Max. switching current 5A (AC)
Min. switching capacity*
1
100mA 5V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000M (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between contact sets 1,000 Vrms for 1 min. (Detection current: 10 mA)
Between open contacts 1,000 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 4,000 Vrms for 1 min. (Detection current: 10 mA)
Temperature rise (coil)
Max. 45C 113F
(with nominal coil voltage and at 3 A contact
carrying current, at 70C 158F)
Max. 45C 113F
(with nominal coil voltage and at 5 A contact
carrying current, at 70C 158F)
Surge breakdown voltage*
2
(Between contact and coil) (Initial)
10,000 V
Operate time (at nominal voltage) (at 20C 68F) Max. 15 ms (excluding contact bounce time.)
Release time (at nominal voltage) (at 20C 68F) Max. 15 ms (excluding contact bounce time) (With diode)
Mechanical
characteristics
Shock resistance
Functional 200 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10s.)
Destructive 1,000 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10s.)
Destructive 10 to 55 Hz at double amplitude of 1.5 mm
Expected life
Mechanical Min. 10
6
(at 180 times/min.)
Electrical (at 20 times/min.) Min. 510
4
(ON: OFF=1.5s: 1.5s) (at nominal switching capacity)
Conditions
Conditions for operation, transport and storage*
3
Ambient temperature: –40C to +70C –40F to +158F,
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature),
Air pressure: 86 to 106kPa
Max. operating speed 20 times/min. (at nominal switching capacity)
Unit weight Approx. 13 g .46 oz
1. Max. switching power (AC resistive load) 2-(1). Life curve (250 V AC resistive load) for
5A type
2-(2). Life curve (125 V AC resistive load) for
3A type
10
3
5
0 300100
Contact voltage, V
Contact current, A
ALA2PF12
ALA2F12
100
10
1
10 2345
250V AC resistive load
Contact current, A
Life, ×10
4
100
10
1
1023
125V AC resistive load
Contact current, A
Life, ×10
4