KT2 Series Temperature Controller
ARCT1B237E ’04.5
New
KT2
Temperature
Controller
Compact temperature
controller (DIN 48
24) that
can support pattern control
FEATURES
1. Nine step pattern control possible.
Despite DIN 48 x 24 size, selection is
possible of control with fixed set point and
nine step pattern control.
2. Multi-input
Versatile thermocouple, RTD, DC voltage
and DC current input for temperature
detecting sensors.
3. Simple operation enables highly
accurate temperature control
All required operations can be enabled by
the front keys and highly accurate PID
control mode ensures an input span of
±0.2%.
4. Adding in optional functions
(heating/cooling and communication
functions), 24 product types are
available.
5. KT series complies with UL, CSA
standards and CE marking.
6. Adopt RS485 and Modbus protocol
for communication specification
* In the configuration above, FP
requires a
communication cassette (FPG-COM3).
* Modbus is a communication protocol
developed for PLCs by Modicon Inc.
RS-485
KT2
OFF
MODE
OUT
EV1
EV2
OUT
PV
MEMO/STEP
SV AT T/R
KT2
OFF
MODE
OUT
EV1
EV2
OUT
PV
MEMO/STEP
SV AT T/R
KT2
OFF
MODE
OUT
EV1
EV2
OUT
PV
MEMO/STEP
SV AT T/R
Up to 31 units can be connected
FP Programmable Controller
(Matsushita Electric Works)
(Sample System Configuration)
Name and functions of the sections
KT2
OFF
MODE
OUT
EV1
EV2
OUT
PV
MEMO/STEP
SV AT T/R
1
2
3456
10 11 12 13
7
8
9
PV/SV display (red): Indicates the input value and setting value. During setting mode, characters
and setting value of the setting item are indicated in turn.
MEMO/STEP display (green): Indicates memory number during fixed value control. Indicates step number
during program control.
PV indicator (red): Lights up when the input value (PV) is indicated.
SV indicator (green): Lights up when main setting value (SV) is indicated.
AT indicator (yellow): Flashes during AT (auto-tuning).
T/R indicator (yellow): Flashes during serial communication (Lit while sending data, Unlit while
receiving data)
OUT indicator (green): Lights up when control output or OUT1 (Heating side, option Heating/Cooling
control) is ON. (For DC current output type, it flashes corresponding to the
manipulated variable in a 0.25 second cycle)
EV1 indicator (red): Lights up when Event output 1 or OUT2 (Cooling side, option Heating/Cooling
control) is ON.
EV2 indicator (red): Lights up when Event output 2 is ON.
Increase key ( ): Increases the numeric value.
Decrease key ( ): Decreases the numeric value.
Mode key ( ): Selects the setting mode or registers the setting value.
(By pressing the Mode key, the setting value or selected value can be
registered)
OUT/OFF key ( ): The control output OUT/OFF or program control RUN/STOP can be switched.