Multi Purpose Camera Operating Instructions

- 10 -
HD SDI output connector [HD SDI OUT]
HD SDI signal output is given by this line.
G/L input connector [G/L IN]
For gen-lock with the camera, the external sync signal (black burst) or tri-level sync
signal is supplied to this input connector.
Operate indicator
Green LED lamp lights to indicate that the specified DC 12 V power is supplied to the
interface connector .
Cooling fan
Do not block or obstruct the ventilation during operation. It may otherwise cause
internal heating or fire.
The life of this fan is approximately 30,000 hours (at room temp. 77 °F (25 °C)).
Replace the fan as needed.
(When the room temperature is higher than 95 °F (35 °C), replace the fan 30 %
earlier.)
Be sure to ask the dealer for the replacement.
Interface connector [I/F]
Pin No. Signal
1 Gen-lock signal GND
2 Not used
3 Not used
4 TX_N (EIA422)/TXD (EIA232) output
5 RX_N (EIA422)/RXD (EIA232) input
6 DC power supply input (+12 V)
7 Gen-lock signal input
8 DC GND
9 TX_P (EIA422) output
10 RX_P (EIA422) input
11 GND
12 Not used
13
GND
14
GND
15 GND
When supplying DC power, supply the DC +12 V voltage to pin 6 and connect GND to
pin 8.