Datasheet

AEQ1
3
5. Operating characteristics
Notes: 1. The above indicates the characteristics when operating the pushbutton from the vertical direction.
2. Indicates operation load for NO contact to achieve ON status.
3. Indicates position for NC contact to achieve OFF status.
4. Indicates position for NO contact to achieve ON status.
5. Although there is some overlap in the range of the operating position (O.P.) on the NC and NO sides due to the tolerance, in actuality there is always an intermediate
OFF range (the NC and NO sides will never ON at the same time.)
6. Indicates position for NC contact to achieve ON status.
7. Indicates position for NO contact to achieve OFF status.
CONTACT ARRANGEMENT
Item
Standard value
Pin plunger Leaf lever Simulated leaf lever
Operating Force (max. O.F.) *
Note 2
1.2 N 1.7 N 1.5 N
Total travel Force (max. T.F.) reference value (1.8 N) (3.1 N) (2.8 N)
Free Position (max. F.P.) From mounting boss and hole center line 9.2 mm 11.5 mm 14.4 mm
Operating Position on NC side [O.P. (N.C.)] *
Note 3
From mounting boss and hole center line 8.7±0.3 mm 9.8±0.5 mm 12.5±0.5 mm
Operating Position on NO side [O.P. (N.O.)] *
Note 4
From mounting boss and hole center line 8.4±0.3 mm 9.3±0.5 mm 12.0±0.5 mm
Release Position on NC side [R.P. (N.C.)] *
Note 6
From mounting boss and hole center line 8.8±0.3 mm 10.1±0.5 mm 12.9±0.5 mm
Release Position on NO side [R.P. (N.O.)] *
Note 7
From mounting boss and hole center line 8.5±0.3 mm 9.6±0.5 mm 12.4±0.5 mm
Over travel on NC side [min. O.T. (N.C.)] 2.5 mm 3.1 mm 3.3 mm
Over travel on NO side [min. O.T. (N.O.)] 2.2 mm 2.6 mm 2.8 mm
Total Travel Position (T.T.P.) reference value From mounting boss and hole center line (5.9 mm) (6.2 mm) (8.7 mm)
OPERATION CONCEPT DIAGRAM
Contact form: terminal type
DATA
Applicable current range (reference)
T. F.
R.F.
O.F.
Stroke
Standard (mounting boss and hole
center diameter or standoff)
Operation load
Contact pressure
Range of possible use
NC side
NO side
0
0
(OFF)
NO side
NC side
Operation
load
O.T.(NC)
O.T.(NO)
O.P.(NC)
O.P.(NO)
R.P.(NC)
R.P.(NO)
F. P.
T. T.P.
Applicable range
100mA
0.1mA
0
30V3VDC
COM NO NC
03/2010