Datasheet
DZ-S (ADZS)
–3–
ASCTB389E 201703-T
DIMENSIONS (mm inch)
Vertical terminal type
Terminal arrangement example
SAFETY STANDARDS
This relay is IEC/EN 62055-31 UC3 certified by VDE
NOTES
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
External dimensions
7.5
.295
2.5
.098
27.2
1.071
1.5
.059
6.7
.264
38.5±0.5 10.4
1.516±.020 .409
5.0
.197
5.0
.197
.317
8.05
2 coil
latching only
54
321
5.4
.213
4.3 dia.
.169 dia.
15.2
.598
17.5±0.5
.689±.020
4.3 dia.
.169 dia.
8.75
.344
0.64
.025
11.00
.433
11.0
.433
8.75
.344
6.5
.256
.236±.016
6.0±0.4
30.0±0.5
1.181±.020
12.0
.472
.055
1.4
.118
3.0
1.5
.059
.276
7.0
Schematic (Top view)
(Set condition)
−−+
−+
231
5
4
5
4
23
1 coil latching 2 coil latching
CAD Data
General tolerance: ±0.3 ±.012
Design 1 Design 2 Design 3
Braided wire and Heat
shrinkable tube
Shunt
* Special orders such as, terminal shape, braided wire length,
with/without shunt etc. are available.
1. For cautions for use, please read
“GENERAL APPLICATION
GUIDELINES”.
2. This relay is designed to dust cover
type. Malfunction and contact failure
may result if small insects get inside
the relay.
3. Do not apply excessive pressure on
the terminals. This could adversely
affect relay performance. Use a
washer in order to prevent
deformation.
Keep the installation torque to within
1.2 to 1.4 N·m (12 to 14 kgf·cm). Also,
use a spring washer to prevent it from
loosening.
4. It is recommended to apply rated
coil voltage for Min. 100ms pulse
across the ambient temperature and
condition change through service life.
the coil to secure the sure operation
considering
5. Please do not continuously
energize to coil over 10 seconds.