Datasheet

DW (ADW)
2
ds_61A10_en_dw: 191113D
TYPES
1. Standard type (8A) (Reflow compatible type)
Standard packing: Carton: 100 pcs.; Case: 500 pcs.
Note: Carton packing is standard. Tube packing type is also available. Please consult us for details.
2. Standard type (8A) (IEC60335-1 compliant type)
Standard packing: Carton: 100 pcs.; Case: 500 pcs.
Note: Carton packing is standard. Tube packing type is also available. Please consult us for details.
3. Inrush type (16A, Inrush current 100A)
Standard packing: 100 pcs.; Case: 500 pcs.
Note: Carton packing is standard. Tube packing type is also available. Please contact us for details.
RATING
1. Coil data
1) 1 coil latching type
2) 2 coil latching type
*Pulse drive (JIS C 5442-1996)
Contact arrangement Nominal coil voltage
Part No.
1 coil latching type 2 coil latching type
1 Form A
3V DC ADW1103W ADW1203W
5V DC ADW1105W ADW1205W
6V DC ADW1106W ADW1206W
9V DC ADW1109W ADW1209W
12V DC ADW1112W ADW1212W
24V DC ADW1124W ADW1224W
Contact arrangement Nominal coil voltage
Part No.
1 coil latching type 2 coil latching type
1 Form A
3V DC ADW1103TW ADW1203TW
5V DC ADW1105TW ADW1205TW
6V DC ADW1106TW ADW1206TW
9V DC ADW1109TW ADW1209TW
12V DC ADW1112TW ADW1212TW
24V DC ADW1124TW ADW1224TW
Contact arrangement Nominal coil voltage
Part No.
1 coil latching type 2 coil latching type
1 Form A
3V DC ADW1103HTW ADW1203HTW
5V DC ADW1105HTW ADW1205HTW
6V DC ADW1106HTW ADW1206HTW
9V DC ADW1109HTW ADW1209HTW
12V DC ADW1112HTW ADW1212HTW
24V DC ADW1124HTW ADW1224HTW
Nominal coil
voltage
Set voltage
(at 20C 68F)
Reset voltage
(at 20C 68F)
Nominal operating
current
[10%] (at 20C 68F)
Coil resistance
[10%] (at 20C 68F)
Nominal operating
power
Max. applied voltage
(at 20C 68F)
3V DC
*80%V or less of
nominal voltage
(Initial)
*80%V or less of
nominal voltage
(Initial)
66.7mA 45
200mW
110%V of nominal
voltage
5V DC 40.0mA 125
6V DC 33.3mA 180
9V DC 22.2mA 405
12V DC 16.7mA 720
24V DC 8.3mA 2,880
Nominal coil
voltage
Set voltage
(at 20C 68F)
Reset voltage
(at 20C 68F)
Nominal operating
current
[10%] (at 20C 68F)
Coil resistance
[10%] (at 20C 68F)
Nominal operating
power
Max. applied voltage
(at 20C 68F)
Set coil Reset coil Set coil Reset coil Set coil Reset coil
3V DC
*80%V or less of
nominal voltage
(Initial)
*80%V or less of
nominal voltage
(Initial)
133.3mA 133.3mA 22.5 22.5
400mW 400mW
110%V of nominal
voltage
5V DC 80.0mA 80.0mA 62.5 62.5
6V DC 66.7mA 66.7mA 90 90
9V DC 44.4mA 44.4mA 202.5 202.5
12V DC 33.3mA 33.3mA 360 360
24V DC 16.7mA 16.7mA 1,440 1,440