Datasheet
DW (ADW)
3
ds_61A10_en_dw: 191113D
2. Specifications
Notes:
*1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2. Wave is standard shock voltage of 1.250s according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions
in NOTES on page 5.
*4. Allowable range when in original packaging is –40C to +70C –40F to +158F.
REFERENCE DATA
Characteristics Item
Specifications
Standard type (8A Reflow compatible type,
IEC60335-1 compliant type)
Inrush type (16A IEC60335-1 compliant type)
Contact
Arrangement 1 Form A
Contact resistance (Initial) Max. 100 m (By voltage drop 6 V DC 1A)
Contact material AgSnO
2 type
Rating
Nominal switching capacity (resistive load) 8A 250V AC 16A 277V AC
Max. switching power (resistive load) 2,000V A 4,432V A
Max. switching voltage 250V AC 277V AC
Max. switching current 8A AC 16A AC
Nominal operating power 200mW (1 coil latching type), 400mW (2 coil latching type)
Min. switching capacity (Reference value)*
1
100mA 5 V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000M (at 500V DC, Measurement at same location as “Breakdown voltage” section)
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1min. (Detection current: 10mA)
Between contact and coil 5,000 Vrms for 1min. (Detection current: 10mA)
Temperature rise (coil) (at 85C 185F) Max. 35C 95F (By resistive method, contact carrying current: 8A, Coil: de-energized)
Surge breakdown voltage*
2
(Between contact and coil)
12,000 V (Initial)
Set time (at 20C 68F) Max. 15 ms (Nominal voltage applied to the coil, excluding contact bounce time)
Reset time (at 20C 68F) Max. 15 ms (Nominal voltage applied to the coil, excluding contact bounce time)
Mechanical
characteristics
Shock resistance
Functional 100 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10s)
Destructive 1,000 m/s
2
(Half-wave pulse of sine wave: 6 ms)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 2 mm (Detection time: 10s)
Destructive 10 to 55 Hz at double amplitude of 3 mm
Expected life
Mechanical Min. 10
6
(at 180 times/min.)
Electrical
Resistive load
Both types: Min. 5 10
4
(at 8A 250V AC,
at 20 times/min.)
IEC60335-1 type: Min. 10
5
(at 5A 250V AC,
at 20 times/min.)
Min. 5 10
4
(at 16A 277V AC, at 6 times/min.)
Min. 5 10
4
(at 8A 250V AC, at 20 times/min.)
Inrush current —
Min. 2.5 10
4
[Inrush 100A 600W (120V AC)
Tungsten]
Cycle rate ON:OFF = 1s:59s
Conditions
Conditions for operation, transport and
storage*
3
*
4
Temperature: –40C to +85C –40F to +185F
Humidity: 5 to 85% R.H. (Not freezing and
condensing at low temperature)
Temperature: –40C to +85C –40F to +185F
(8A and less),
–40C to +70C –40F to +158F
(Over 8A to 16A)
Humidity: 5 to 85% R.H. (Not freezing and
condensing at low temperature)
Unit weight Approx. 8 g .28 oz
1. Max. switching capacity (AC resistive load) 2. Set time
Tested sample: ADW1106, 15 pcs
Ambient temperature: 28C 82.4F
Contact load: 5V DC, 10mA
3. Reset time
Tested sample: ADW1106, 15 pcs
Ambient temperature: 28C 82.4F
Contact load: 5V DC, 10mA
10001
100
10
8
1
10 100 250
Contact voltage, V
Inrush type
Standard type
Contact current, A
Max.
Min.
130120110100908070
7.0
6.0
5.0
4.0
3.0
2.0
1.0
0.0
Coil applied voltage, %V
Set time, ms
Max.
Min.
130120110100908070
7.0
6.0
5.0
4.0
3.0
2.0
1.0
0.0
Coil applied voltage, %V