INSULATION CHARACTERISTICS (IEC61810-1)
* Actual value
NOTES
Item Characteristics
Clearance/Creepage distance (IEC61810-1) 9.5mm/12.7mm
Category of protection (IEC61810-1) RT II
Tracking resistance (IEC60112) 175V
Insulation material group III a
Over voltage category III
Rated voltage 250 V
Pollution degree 2
Type of insulation (Between contact and coil) 4,000 V
Type of insulation (Between open contacts) 1,500 V
1. For cautions for use, please read
“GENERAL APPLICATION
GUIDELINES”.
2. Regarding the set/reset pulse time
of the latching type relay, it is
recommended to apply rated
voltage for minimum 100ms pulse
across the coil to secure the sure
operation considering the ambient
temperature and condition change
through service life.