Data Sheet
Panasonic North America
Air Conditioning Division
1690 Roberts Blvd., NW, Suite 110
Kennesaw, GA 30144
us.panasonic.com/aircon
Features
Controls Microprocessor
Remote Controller (Wired Remote Included)
(Wireless Remote Optional)
Temperature Control IC Thermostat
Timer 72 Hr. On/Off
Night Setback N/A
Air Louver, Horizontal Manual
Air Louver, Vertical Automatic
Power Failure Automatic
Changeover
Built-In
Heating/Cooling Automatic
Changeover
Built-In
Self-Diagnosis Built-In
Air Filter Washable, Anti-Mold
Operating Range
Indoor Air Intake Temp
Outdoor Air Intake Temp
Cooling (Max) 95F DB/71F WB 115F DB
Cooling (Min) 67 DB/57F WB 0F DB
Heating (Max) 80F DB/67F WB 75F DB/65F WB
Heating (Min) -DB/-WB 5F DB
Performance Data @ ARI Standard Conditions (230/208V)
Cooling
Total Capacity (BTU/H) 39,000 (9,500 - 39,000)
Sensible Capacity (BTU/H) 23,560
Latent Capacity (BTU/H) 15,440
SEER 15.6
Dehumidification (Pints/H) 12.6
Amps (A) 21.1/23.3
Power Inputs (W) 4,140/4,140
Outdoor Sound Rating (dB-A) High 53
Heating
Total Capacity (BTU/H) 44,500 (8,000 - 44,500)
HSPF 10.2
Amps (A) 18.6/20.6
Max Amps (A) 18.6/20.6
Power Inputs (W) 3,630/3,630
Back-up Strip Heather (KW) N/A
Outdoor Sound Rating (dB-A) High 53
Option
Refrigerant Line Set Available
Fresh Air Intake Knock-out
Airduct Extension N/A
Indoor Frame Extension N/A
Condensate Drain Pump Optional Accessory
Non-Removeable Locking
Remo-con Bracket
Available