Data Sheet

MB1500 prevents critical equipment
from losing setup configuration, stored
data and hard-disk crashes. Shuts off
projection equipment via IR control to
allow the projector bulbs to go through
a proper cool-down cycle before
shutting off.
www.panamax.com
MB1500
FOR YOUR
HOME THEATER
SYSTEM
A Fully Programmable, Uninterruptible Power Supply,
Voltage Regulator & Power Conditioner
MB1500
COMBINES POWER MANAGEMENT, SURGE PROTECTION WITH AVM
AND BATTERY BACKUP TO PROVIDE THE COMPLETE SOLUTION!
Features
BlueBolt™ Remote Power Management technology provides secure, hosted IP
(Internet Protocol) system control. Sold separately, conatct Panamax for information.
MB1500 is Compatible!
B
LT
Blue
• 1500 VA Rated Battery Backup
• True Sine Wave Output
• AVM Automatic Voltage Monitoring
• LiFT Linear Filtering Technology Noise Filtration
• Protect or Disconnect Voltage Protection
• Voltage Regulation
• Dual Learning IR Output Controls
• USB Interface
• RS-232 with Open Source Protocol
• Fully Programmable
• Four Programmable Critical Load
Management AC Outlet Groups
• IP Card Module for Remote Control Via
Internet (BlueBOLT™ Sold Separately,
(See below)
• Battery Extension Pack Available To
Extend Runtme (BATT1500-EXT Sold Separately)
See pg. 2
MB1500 SPECIFICATIONS
Specifications subject to change due to product upgrades and improvements.
Input
Voltage 85 – 137 VAC
Frequency 57 – 63 Hz
AC Power
Surge Protection: Non-sacrificial AVM
(Automatic Voltage Monitoring)
Current Rating 12 A maximum (7.5 A maximum
battery load recommended)
Overvoltage Shutoff, fast rise: 150 ± 5 V
Overvoltage Shutoff, slow rise: 140 ± 5 V
Undervoltage Shutoff: 90 ± 5 V
Noise Filtration: 40dB min from 100 kHz-2MHz
75dB max @ 270kHz
Linear Attenuation Curve: From 0.05 - 100 Ohms
line impedance
Automatic Voltage Regulation,
Sensitive Mode Capture Range: 98 – 135 V
Automatic Voltage Regulation,
Sensitive Mode Output Range: 120 ± 5%
Automatic Voltage Regulation,
Standard Mode Capture Range: 90 – 140 V
Automatic Voltage Regulation,
Standard Mode Output Range: 120 ± 10%
UPS Output
Voltage 120 ± 5 V True Sine Wave
Frequency 60 Hz ± 1%
UPS Output Capacity 1500VA 600W @ 0.6pf
UPS Backup Time. (full load) 12 minutes
UPS Backup Time. (half load) 30 minutes
Transfer Time < 4ms
L617 REV. C 10/09