Operator's Manual
Table Of Contents
- What is new in publication version 7.2?
- 1 Introduction
- 1.1 Before you start
- 1.2 Important safety instructions and additional information
- Important information regarding safety
- Disposal of the system
- Product safety
- General care
- Accessory box
- Meter
- Power off meter
- Automatic power-off
- Shut down meter
- Automatic shutdown
- Battery Pack
- Touchscreen
- Electromagnetic compatibility (EMC)
- Electrostatic discharge (ESD)
- Wireless connectivity
- Radiofrequency radiation exposure information
- Local Area Network: protection from unauthorized access
- Wired network connection
- 1.3 System components
- 1.4 Overview of the meter
- 1.5 Overview of the code key reader
- 1.6 Overview of the Accu-Chek Inform II Base Unit
- 1.7 Overview of the Accu-Chek Inform II Base Unit Hub
- 1.8 Overview of the accessory box
- 1.9 Reagents and consumables
- 1.10 Instructions for initial setup
- 2 Powering Up and Entering an Operator ID
- 3 Patient Glucose Testing
- 3.1 Information regarding blood glucose testing
- 3.2 Performing a patient glucose test
- Overview of test procedure
- Entering or selecting the patient ID
- Entering the patient ID manually
- Selecting the patient ID from a list
- Entering a patient ID with barcode scanner
- Confirming or selecting the test strip lot
- Patient identification information
- Inserting test strips
- Obtaining a blood sample
- Applying a blood sample
- Results screen
- Adding comments
- Add barcode content to a result
- Additional Patient Test
- 4 Glucose Control Testing
- 5 Review Results
- 6 Storing Test Strip, Control Solution, and Linearity Solution Information in the Meter
- 7 Linearity Testing
- 8 Proficiency Testing
- 9 Initial Startup
- 9.1 Connecting the base unit
- 9.2 Installing or replacing the battery pack
- 9.3 Docking the meter
- 9.4 Initial setup on the meter
- 9.5 Opening the Setup Menu
- 9.6 Date and time format
- 9.7 Display options and optional tests
- 9.8 Options for test strips
- 9.9 Options for glucose control tests
- 9.10 Value ranges (normal, critical, reportable)
- 9.11 Options for Operator ID Entry
- 9.12 Patient ID options
- 9.13 Creating a setup password
- 9.14 Setting the date and time
- 9.15 Beeper options
- 10 Maintenance and Care
- 11 Troubleshooting
- 12 General Product Information
- A Appendix
- B Appendix
- C Supplement for Other Test Entry
- D Supplement for Observed Test Sequence
- E Supplement for Enhanced Workflows
- F Appendix for Accu-Chek Inform II Base Unit (legacy version)
- G Limited Warranty
- Index
General Product Information • 12
183
08424705001 (04) 2021-06 USA • Accu-Chek Inform II Operator’s Manual Version 7.2
12 General Product Information
12.1 Technical data
Specification Meter Base unit Power supply unit
Height 1.73 in / 44 mm (max.) Base Unit:
4.84 in / 123 mm (max.)
Base Unit Light:
4.33 in / 110 mm (max.)
1.38 in / 35 mm +
A
C plug (1.1-1.6 in /
28-40 mm)
Width 3.74 in / 95 mm (max.) Base Unit:
5.12 in / 130 mm (max.)
Base Unit Light:
4.65 in / 118 mm (max.)
2.01 in / 51 mm
Length 7.60 in / 193 mm (max.) Base Unit:
5.12 in / 130 mm (max.)
Base Unit Light:
4.06 in / 103 mm (max.)
3.43 in / 87 mm
Weight approx. 347 g (with
rechargeable battery)
Base Unit:
671 g with wall mount
Base Unit Light:
573 g with wall mount
170 g
User interface Touchscreen and barcode
scanner
Base Unit:
LED (tricolor: red, green,
blue)
Base Unit Light:
LED (bicolor: red, green)
LED: green
Display resolution
(touchscreen)
320 x 240 pixel N/A N/A
Memory – 1,000 Results
– 5,000 Operator ID records
– 4,000 Patient ID records
– 300 Predefined comments
– 20 Code Files
(test strip lots)
– 100 Reagent Lots (control,
linearity, OTE)
– 250 Events
N/A N/A