Operator's Manual
Table Of Contents
- What is new in publication version 7.2?
- 1 Introduction
- 1.1 Before you start
- 1.2 Important safety instructions and additional information
- Important information regarding safety
- Disposal of the system
- Product safety
- General care
- Accessory box
- Meter
- Power off meter
- Automatic power-off
- Shut down meter
- Automatic shutdown
- Battery Pack
- Touchscreen
- Electromagnetic compatibility (EMC)
- Electrostatic discharge (ESD)
- Wireless connectivity
- Radiofrequency radiation exposure information
- Local Area Network: protection from unauthorized access
- Wired network connection
- 1.3 System components
- 1.4 Overview of the meter
- 1.5 Overview of the code key reader
- 1.6 Overview of the Accu-Chek Inform II Base Unit
- 1.7 Overview of the Accu-Chek Inform II Base Unit Hub
- 1.8 Overview of the accessory box
- 1.9 Reagents and consumables
- 1.10 Instructions for initial setup
- 2 Powering Up and Entering an Operator ID
- 3 Patient Glucose Testing
- 3.1 Information regarding blood glucose testing
- 3.2 Performing a patient glucose test
- Overview of test procedure
- Entering or selecting the patient ID
- Entering the patient ID manually
- Selecting the patient ID from a list
- Entering a patient ID with barcode scanner
- Confirming or selecting the test strip lot
- Patient identification information
- Inserting test strips
- Obtaining a blood sample
- Applying a blood sample
- Results screen
- Adding comments
- Add barcode content to a result
- Additional Patient Test
- 4 Glucose Control Testing
- 5 Review Results
- 6 Storing Test Strip, Control Solution, and Linearity Solution Information in the Meter
- 7 Linearity Testing
- 8 Proficiency Testing
- 9 Initial Startup
- 9.1 Connecting the base unit
- 9.2 Installing or replacing the battery pack
- 9.3 Docking the meter
- 9.4 Initial setup on the meter
- 9.5 Opening the Setup Menu
- 9.6 Date and time format
- 9.7 Display options and optional tests
- 9.8 Options for test strips
- 9.9 Options for glucose control tests
- 9.10 Value ranges (normal, critical, reportable)
- 9.11 Options for Operator ID Entry
- 9.12 Patient ID options
- 9.13 Creating a setup password
- 9.14 Setting the date and time
- 9.15 Beeper options
- 10 Maintenance and Care
- 11 Troubleshooting
- 12 General Product Information
- A Appendix
- B Appendix
- C Supplement for Other Test Entry
- D Supplement for Observed Test Sequence
- E Supplement for Enhanced Workflows
- F Appendix for Accu-Chek Inform II Base Unit (legacy version)
- G Limited Warranty
- Index
Troubleshooting • 11
177
08424705001 (04) 2021-06 USA • Accu-Chek Inform II Operator’s Manual Version 7.2
E-FCG Invalid Scan: Invalid Scan. The scan returned an entry > 20 characters. Please see your System
Administrator.
E-FCH Invalid Range: The range entered must be between 10 and 600 mg/dl. Please re-enter.
E-FCK Invalid Range: The Normal Range Hi value must be greater than the Normal Range Lo value
(currently *). Please re-enter.
<* is the Normal Range value defined by the institution on the device>
E-FCL Invalid Range: The Critical Range Hi value must be greater than the Critical Range Lo value
(currently *). Please re-enter.
<* is the Critical Range value defined by the institution on the device>
E-FCM Invalid Range: The Reportable Range Hi value must be greater than the Reportable Range Lo
value (currently *). Please re-enter.
<* is the Reportable Range value defined by the institution on the device>
E-FCN Invalid Range: The Reportable Range Lo value must be less than or equal to the Critical Range Lo
value (currently *). Please re-enter.
<* is the Critical Range value defined by the institution on the device>
E-FDB Invalid Range: The Reportable Range Hi value must be greater than or equal to the Critical Range
Hi value (currently *). Please re-enter.
<* is the Critical Range value defined by the institution on the device>
E-FDC Invalid Range: The Critical Range Hi value must be greater than or equal to the Normal Range Hi
value (currently *). Please re-enter.
<* is the Normal Range value defined by the institution on the device>
E-FDD Invalid QC Hours: QC Hours must be greater than 0 and less than 10,000. Please re-enter.
E-FDF Invalid Strip Limit: QC Strips must be greater than 0 and less than 1,000. Please re-enter.
E-FDH Invalid Strip Lot Barcode: The scanned in barcode is invalid for a Strip lot barcode. Please scan in
a valid barcode, or see your System Administrator
E-FDK Undefined Strip Lot: The barcode scanned strip lot: * is not defined on this meter. Please see your
System Administrator.
<* is the test strip lot number>
E-FDL Invalid Limit: The length entered must be between 0 and 20. Please enter a valid length.
E-FDM Invalid Limit: The Operator ID Max length must be greater than or equal to the Operator ID Min
length (currently *). Please re-enter.
<* is the Operator ID minimum length defined by the institution >
E-FDN Invalid Limit: The Patient ID Max length must be greater than or equal to the Patient ID Min length
(currently *). Please re-enter.
<* is the Patient ID minimum length defined by the institution >
E-FFB Invalid Operator Barcode: The barcode scanned is not a valid operator barcode. Please scan a
valid operator barcode or see your System Administrator.
Error Messages
Code Text