Operator's Manual
Table Of Contents
- What is new in publication version 7.2?
- 1 Introduction
- 1.1 Before you start
- 1.2 Important safety instructions and additional information
- Important information regarding safety
- Disposal of the system
- Product safety
- General care
- Accessory box
- Meter
- Power off meter
- Automatic power-off
- Shut down meter
- Automatic shutdown
- Battery Pack
- Touchscreen
- Electromagnetic compatibility (EMC)
- Electrostatic discharge (ESD)
- Wireless connectivity
- Radiofrequency radiation exposure information
- Local Area Network: protection from unauthorized access
- Wired network connection
- 1.3 System components
- 1.4 Overview of the meter
- 1.5 Overview of the code key reader
- 1.6 Overview of the Accu-Chek Inform II Base Unit
- 1.7 Overview of the Accu-Chek Inform II Base Unit Hub
- 1.8 Overview of the accessory box
- 1.9 Reagents and consumables
- 1.10 Instructions for initial setup
- 2 Powering Up and Entering an Operator ID
- 3 Patient Glucose Testing
- 3.1 Information regarding blood glucose testing
- 3.2 Performing a patient glucose test
- Overview of test procedure
- Entering or selecting the patient ID
- Entering the patient ID manually
- Selecting the patient ID from a list
- Entering a patient ID with barcode scanner
- Confirming or selecting the test strip lot
- Patient identification information
- Inserting test strips
- Obtaining a blood sample
- Applying a blood sample
- Results screen
- Adding comments
- Add barcode content to a result
- Additional Patient Test
- 4 Glucose Control Testing
- 5 Review Results
- 6 Storing Test Strip, Control Solution, and Linearity Solution Information in the Meter
- 7 Linearity Testing
- 8 Proficiency Testing
- 9 Initial Startup
- 9.1 Connecting the base unit
- 9.2 Installing or replacing the battery pack
- 9.3 Docking the meter
- 9.4 Initial setup on the meter
- 9.5 Opening the Setup Menu
- 9.6 Date and time format
- 9.7 Display options and optional tests
- 9.8 Options for test strips
- 9.9 Options for glucose control tests
- 9.10 Value ranges (normal, critical, reportable)
- 9.11 Options for Operator ID Entry
- 9.12 Patient ID options
- 9.13 Creating a setup password
- 9.14 Setting the date and time
- 9.15 Beeper options
- 10 Maintenance and Care
- 11 Troubleshooting
- 12 General Product Information
- A Appendix
- B Appendix
- C Supplement for Other Test Entry
- D Supplement for Observed Test Sequence
- E Supplement for Enhanced Workflows
- F Appendix for Accu-Chek Inform II Base Unit (legacy version)
- G Limited Warranty
- Index
136
08424705001 (04) 2021-06 USA • Accu-Chek Inform II Operator’s Manual Version 7.2
9.6 Date and time format
Use this menu to select the date and time format for the
display. You can also choose whether the operator is
allowed to edit date and time (optionally with password
required, see “Creating a setup password” on page 145).
1 Touch the desired option to enable it:
■ Date/Time Editing
– Allowed: Enables the operator to edit the date and
time.
– Password Needed: Enables the operator to edit the
date and time only after entering a password.
– Not Allowed: The operator cannot edit date or time.
■ Time Format
– 12 hour (AM/PM)
– 24 hour
■ Date Format
– mm/dd/yy: The date is displayed in two-digit
month/day/year format
– dd.mm.yy: The date is displayed in two-digit day/
month/year format
2 Touch to save the settings,
or
touch to exit this menu without saving any
changes.
The display returns in both cases to the Setup Menu.
When using a data management system for configura-
tion, it is possible to fully disable the Date/Time Editing
option.
Date/Time Options
Date/Time Editing
Allowed
Password Needed
Time Format
12 hour (AM / PM)
24 hour
Date Format
mm/dd/yy
dd.mm.yy
Not Allowed
12:48 pm
03/17/20