Profile Dimensions
Profile
(mm)
Thickness
(mm)
Length
(m)
Width
(mm)
Effective
Width (mm)
Side-Lap
(%)
920 885 3.8
1100 1062 3.4
177 / 51 1.0 – 3.0 1.5 - 11.6
1100 885 19.5
(1100)
Load / Span Data
Maximum Roof Span (mm)
Load
(kg/m
2
)
2.0 mm 2.5 mm 3.0 mm
50
1400 1600 1800
80
1300 1500 1700
110
1200 1400 1600
The dimensions depicted do not supersede the requirements of local construction codes.
Purlins spans are based on the panel’s structural properties, sheet deflection, potential wind and snow
load, hail and other applicable factors according to construction practice, professional expertise and
previous field experience.
In vertical walls the spans can be increased by 10%.
Minimum recommended slope for a new roof – 10%.
Maximum recommended sheet length – 7.0 m.
Safety
Do not step directly on the sheets - before, during or
after installation.
Work according to local safety regulations.
Use stepping ladder or crawling boards.
Positioning
The sheets must be laid on the roof against the primary direction of wind
and rain.
The PALRUF sheet must be installed without any stresses and deformation.