User's Manual

18
Conditions of Use of Permalog
®
System
1. Deployment of Permalog
®
units should be carried out in accordance with
Palmer Environmental document PDI(E) Issue 1. Mishandling the logger
could result in damage to the antenna (if incorrectly used to lower or raise
the logger) or the sensor (connecting the logger to, or removing it from, the
fitting). Such damage is not covered by Palmer Environmental’s 3-year
warranty and customers are warned that damage to the sensor in
particular is unlikely to be economic to repair.
2. During handling and transportation of Permalog
®
units from place to place,
care must be taken not to bring the communications window into the
magnetic field of a medium or strong strength magnet. Continuous
exposure to a magnetic field can result in variation in the Permalog
®
‘s
internal clock, which will lead to an increased possibility of false alarms.
Particular care must be taken to avoid packing Permalog
®
units “head to
tail”. Remedial work by Palmer Environmental required to correct loggers
that have been affected in this way is not covered by warranty and will be
charged.
3. Due to the strength of the magnet used with Permalog
®
, large quantities of
Permalog
®
units should not be carried by staff with heart pacemakers.
4. The magnet keeper fitted to Permalog loggers should be left attached to
the magnet until the unit is ready to be placed in its logging position. If the
unit is to be moved for any reason the keeper should be refitted to the
magnet. All Permalog units should be transported with the keeper
attached to the magnet.