User's Manual
Table Of Contents
- MicroCorr( Digital
- Users Guide
- MicroCorr( Digital Users Guide
- MicroCorr( Digital Users Guide
- Keypad functions
- _
- Using the MicroCorr( Digital Correlator
- Step 1: Charging and installing batteries
- Step 2: Set up and deployment of Out Stations
- Step 3: Switching on the Correlator
- Correlating
- Main Menu
- Correlate
- File
- Regression Analysis
- Set-up
- Test and Service
- Other System Options
- Correlation Screen
- Pipe data
- Zoom
- Peak Suppression Screen
- View Settings
- Calculate Velocity
- Filters
- Program upgrade (Software and Firmware)
- Upgrade Information
- The File Menu
- The Unit Type Menu
- _
- Technical Specification
- _
- _
- _
- _
- _
- Base station
- ProcessFull digital correlation
- Frequency response0.1 to 5000Hz
- Filter selectionAutomatic Parametric Filtering
- Resolution(0.1m
- DisplayBacklit colour ¼ VGA
- Antennae External antenna/magmount
- Mixed material6 sections
- Correlation filesUp to 30 files stored
- Battery level indicationFor all system units
- Battery typeRechargeable Lithium ion batteries, field replaceable
- Battery life>24 hours continuous use without backlight
- Key functionsCombined correlation/survey mode
- LanguageSelectable via menu
- Operating softwareUser upgradable from www.palmer.co.uk
- Printer outputRS232 to parallel printer
- PC downloadVia PC software, Windows compatible
- Dimensions220mm x 250 x 100mm
- Weight1.8Kg
- Operating temperature-15(C to +50(C
- Shock protectionDrop tested to 1 metre
- EnvironmentalIP65
- EnclosureFully injection-moulded ABS
- ConnectorsMilitary specification Amphenol
- DiagnosticsSelf-test and auto-calibration on power-on
- Radio communicationSingle frequency digital transceiver
- Radio frequencyUHF (local regulations apply)
- ControlsON/OFF (all functions remotely controlled and monitored from Base station) with LED status light
- ConnectionsHeadphones
- Battery typeRechargeable Lithium ion batteries, field replaceable
- Battery life>18 hours
- Hazard indicationFlashing lights (2)
- AntennaExternal antenna
- PortabilityIntegral sensor stowage
- Dimensions210 x 145 x 305mm
- Weight1.6kg
- Environmental IP68
- Housing Fully injection-mouled ABS
- ConnectorsMilitary specification Amphenol
- Shock protectionDrop tested to 1 metre
- TypeDigital sensor with integral high strength magnet
- Frequency range0.1 to 5000Hz
- Dynamic range>90dB
- Dimensions180mm x 50mm diameter
- Weight 1kg
- EnvironmentalIP68, rubber shroud for shock protection
- Connection to Out Station2m cable with strain relief
- _
- _
- _
- _
- _
- Warranty
- Patents
- _
33
Peak Suppression Screen
Press 6(Peak Suppression) To suppress a section of the time delay range from the current
correlation. This may be used to remove known leaks or demand usage that may be hiding
unknown leaks.
Move the dashed cursor line to the start point of the data to be removed and press 1 to select
a start point. A small arrow will appear below the correlation graph. Move the dashed cursor
line along the data to select the stop point. Press 1 again and the section of the data to be
suppressed will disappear from the correlation graph as shown below.
Press Enter to accept the data and a new correlation can be carried out without the
suppressed data. To replace the removed data press 2 delete.