User's Manual
Table Of Contents
- MicroCorr( Digital
- Users Guide
- MicroCorr( Digital Users Guide
- MicroCorr( Digital Users Guide
- Keypad functions
- _
- Using the MicroCorr( Digital Correlator
- Step 1: Charging and installing batteries
- Step 2: Set up and deployment of Out Stations
- Step 3: Switching on the Correlator
- Correlating
- Main Menu
- Correlate
- File
- Regression Analysis
- Set-up
- Test and Service
- Other System Options
- Correlation Screen
- Pipe data
- Zoom
- Peak Suppression Screen
- View Settings
- Calculate Velocity
- Filters
- Program upgrade (Software and Firmware)
- Upgrade Information
- The File Menu
- The Unit Type Menu
- _
- Technical Specification
- _
- _
- _
- _
- _
- Base station
- ProcessFull digital correlation
- Frequency response0.1 to 5000Hz
- Filter selectionAutomatic Parametric Filtering
- Resolution(0.1m
- DisplayBacklit colour ¼ VGA
- Antennae External antenna/magmount
- Mixed material6 sections
- Correlation filesUp to 30 files stored
- Battery level indicationFor all system units
- Battery typeRechargeable Lithium ion batteries, field replaceable
- Battery life>24 hours continuous use without backlight
- Key functionsCombined correlation/survey mode
- LanguageSelectable via menu
- Operating softwareUser upgradable from www.palmer.co.uk
- Printer outputRS232 to parallel printer
- PC downloadVia PC software, Windows compatible
- Dimensions220mm x 250 x 100mm
- Weight1.8Kg
- Operating temperature-15(C to +50(C
- Shock protectionDrop tested to 1 metre
- EnvironmentalIP65
- EnclosureFully injection-moulded ABS
- ConnectorsMilitary specification Amphenol
- DiagnosticsSelf-test and auto-calibration on power-on
- Radio communicationSingle frequency digital transceiver
- Radio frequencyUHF (local regulations apply)
- ControlsON/OFF (all functions remotely controlled and monitored from Base station) with LED status light
- ConnectionsHeadphones
- Battery typeRechargeable Lithium ion batteries, field replaceable
- Battery life>18 hours
- Hazard indicationFlashing lights (2)
- AntennaExternal antenna
- PortabilityIntegral sensor stowage
- Dimensions210 x 145 x 305mm
- Weight1.6kg
- Environmental IP68
- Housing Fully injection-mouled ABS
- ConnectorsMilitary specification Amphenol
- Shock protectionDrop tested to 1 metre
- TypeDigital sensor with integral high strength magnet
- Frequency range0.1 to 5000Hz
- Dynamic range>90dB
- Dimensions180mm x 50mm diameter
- Weight 1kg
- EnvironmentalIP68, rubber shroud for shock protection
- Connection to Out Station2m cable with strain relief
- _
- _
- _
- _
- _
- Warranty
- Patents
- _
22
Set-up
Press 1(Correlate on start-up) Toggles between YES and NO. If set to YES, the control unit
will go straight to the correlate screen after turning on. If set to NO, the control unit will go
straight to the Main Menu after turning on.
Press 2(Default filters) Toggles between CLEAR and RETAIN. If set to CLEAR, in survey
mode, the filters will clear each time a new correlation is processed. If set to RETAIN, in
survey mode, the filters will retain a set filter setting (set by the user) for every correlation
processed.
Press 3(Survey mode range) Toggles between 0.8, 2.4 and 4.0 seconds. Each of these
values provides the time delay range over which the correlator will correlate, where the times
in seconds shows twice the range. For example, over longer distances the 4.0 second range
should be used to give +2 seconds to –2 seconds. If entering pipe data, the survey mode
range automatically defaults to the appropriate setting.
Press 4(Correlation sensors) Toggles between the pairs of sensors to be used. Red-Blue,
Red-Yellow, Blue-Yellow, Base-Red, Base-Blue and Base-Yellow.
Press 5(Radio Mode) Toggles between HIGH power and LOW power. LOW power can be
used over shorter distances and HIGH power over longer distances or areas where a signal
can be interrupted by the environment. The correlator will always default to LOW power when
turning on.