User's Manual
Table Of Contents
- MicroCorr( Digital
- Users Guide
- MicroCorr( Digital Users Guide
- MicroCorr( Digital Users Guide
- Keypad functions
- _
- Using the MicroCorr( Digital Correlator
- Step 1: Charging and installing batteries
- Step 2: Set up and deployment of Out Stations
- Step 3: Switching on the Correlator
- Correlating
- Main Menu
- Correlate
- File
- Regression Analysis
- Set-up
- Test and Service
- Other System Options
- Correlation Screen
- Pipe data
- Zoom
- Peak Suppression Screen
- View Settings
- Calculate Velocity
- Filters
- Program upgrade (Software and Firmware)
- Upgrade Information
- The File Menu
- The Unit Type Menu
- _
- Technical Specification
- _
- _
- _
- _
- _
- Base station
- ProcessFull digital correlation
- Frequency response0.1 to 5000Hz
- Filter selectionAutomatic Parametric Filtering
- Resolution(0.1m
- DisplayBacklit colour ¼ VGA
- Antennae External antenna/magmount
- Mixed material6 sections
- Correlation filesUp to 30 files stored
- Battery level indicationFor all system units
- Battery typeRechargeable Lithium ion batteries, field replaceable
- Battery life>24 hours continuous use without backlight
- Key functionsCombined correlation/survey mode
- LanguageSelectable via menu
- Operating softwareUser upgradable from www.palmer.co.uk
- Printer outputRS232 to parallel printer
- PC downloadVia PC software, Windows compatible
- Dimensions220mm x 250 x 100mm
- Weight1.8Kg
- Operating temperature-15(C to +50(C
- Shock protectionDrop tested to 1 metre
- EnvironmentalIP65
- EnclosureFully injection-moulded ABS
- ConnectorsMilitary specification Amphenol
- DiagnosticsSelf-test and auto-calibration on power-on
- Radio communicationSingle frequency digital transceiver
- Radio frequencyUHF (local regulations apply)
- ControlsON/OFF (all functions remotely controlled and monitored from Base station) with LED status light
- ConnectionsHeadphones
- Battery typeRechargeable Lithium ion batteries, field replaceable
- Battery life>18 hours
- Hazard indicationFlashing lights (2)
- AntennaExternal antenna
- PortabilityIntegral sensor stowage
- Dimensions210 x 145 x 305mm
- Weight1.6kg
- Environmental IP68
- Housing Fully injection-mouled ABS
- ConnectorsMilitary specification Amphenol
- Shock protectionDrop tested to 1 metre
- TypeDigital sensor with integral high strength magnet
- Frequency range0.1 to 5000Hz
- Dynamic range>90dB
- Dimensions180mm x 50mm diameter
- Weight 1kg
- EnvironmentalIP68, rubber shroud for shock protection
- Connection to Out Station2m cable with strain relief
- _
- _
- _
- _
- _
- Warranty
- Patents
- _
16
Correlating
The screen shown on page 15 is the first screen that appears on the control unit when it is
switched on. Once the ENTER key is pressed the system will begin to correlate. Correlation
can be stopped by pressing the ENTER key again.
This can be used for quick surveys without having to input any pipe data.
If the Enter key is pressed the control unit will start to correlate as shown below.
Press ENTER to stop correlation, to return to correlator function options
There is an option to select either the Correlate screen or the Main Menu screen as the first
screen to appear after turning on. This can be selected by using the Set-up screen (option 4)
from the Main Menu.
Date and time changes to
the run time of the
correlation
Time delay
Signal to
Noise Ratio
Scrolling arrows
shows correlation
is in progress