User's Manual
Table Of Contents
- MicroCorr( Digital
- Users Guide
- MicroCorr( Digital Users Guide
- MicroCorr( Digital Users Guide
- Keypad functions
- _
- Using the MicroCorr( Digital Correlator
- Step 1: Charging and installing batteries
- Step 2: Set up and deployment of Out Stations
- Step 3: Switching on the Correlator
- Correlating
- Main Menu
- Correlate
- File
- Regression Analysis
- Set-up
- Test and Service
- Other System Options
- Correlation Screen
- Pipe data
- Zoom
- Peak Suppression Screen
- View Settings
- Calculate Velocity
- Filters
- Program upgrade (Software and Firmware)
- Upgrade Information
- The File Menu
- The Unit Type Menu
- _
- Technical Specification
- _
- _
- _
- _
- _
- Base station
- ProcessFull digital correlation
- Frequency response0.1 to 5000Hz
- Filter selectionAutomatic Parametric Filtering
- Resolution(0.1m
- DisplayBacklit colour ¼ VGA
- Antennae External antenna/magmount
- Mixed material6 sections
- Correlation filesUp to 30 files stored
- Battery level indicationFor all system units
- Battery typeRechargeable Lithium ion batteries, field replaceable
- Battery life>24 hours continuous use without backlight
- Key functionsCombined correlation/survey mode
- LanguageSelectable via menu
- Operating softwareUser upgradable from www.palmer.co.uk
- Printer outputRS232 to parallel printer
- PC downloadVia PC software, Windows compatible
- Dimensions220mm x 250 x 100mm
- Weight1.8Kg
- Operating temperature-15(C to +50(C
- Shock protectionDrop tested to 1 metre
- EnvironmentalIP65
- EnclosureFully injection-moulded ABS
- ConnectorsMilitary specification Amphenol
- DiagnosticsSelf-test and auto-calibration on power-on
- Radio communicationSingle frequency digital transceiver
- Radio frequencyUHF (local regulations apply)
- ControlsON/OFF (all functions remotely controlled and monitored from Base station) with LED status light
- ConnectionsHeadphones
- Battery typeRechargeable Lithium ion batteries, field replaceable
- Battery life>18 hours
- Hazard indicationFlashing lights (2)
- AntennaExternal antenna
- PortabilityIntegral sensor stowage
- Dimensions210 x 145 x 305mm
- Weight1.6kg
- Environmental IP68
- Housing Fully injection-mouled ABS
- ConnectorsMilitary specification Amphenol
- Shock protectionDrop tested to 1 metre
- TypeDigital sensor with integral high strength magnet
- Frequency range0.1 to 5000Hz
- Dynamic range>90dB
- Dimensions180mm x 50mm diameter
- Weight 1kg
- EnvironmentalIP68, rubber shroud for shock protection
- Connection to Out Station2m cable with strain relief
- _
- _
- _
- _
- _
- Warranty
- Patents
- _
13
4. To charge the Out Station batteries they must first be installed. To do this remove the
screws from the battery compartment on the bottom of each Out Station, connect the battery
lead to the connector and insert the battery. Refit the screws and attach the battery charge
lead to the headphone / charge connector on the top of the transmitter. The Out Stations will
turn themselves on to charge.
Remember to turn control unit and Out Stations off after disconnecting charger cables.
Although the batteries are rechargeable, they may eventually need to be replaced. Only
batteries configured to the correct specification and type must be used. These are available
from Palmer Environmental.
TWO OUT STATIONS CONNECTED VIA CHARGER TO MAINS
Unscrew these
2 quick-release
screws to
remove battery
compartment
panel.