Operation Manual
4
Using the latest technology in battery chargers, switch mode chargers convert
110V/220-240V AC power to 12V/24V DC power using electronic components
unlike traditional battery chargers that rely on heavy transformers. This allows
the charger to be light weight and compact without sacrificing on performance.
3. SWITCHMODE TECHNOLOGY
POLARITY PROTECTION
Prevents the output leads from sparking due to accidental reverse connection
or short circuit, making the charger safer to use around batteries.
OUTPUT SHORT PROTECTION
Short circuit connection of the clips: Check clips are not touching each other
OR Check the clips are correctly connected to the battery.
NON BATTERY LINK PROTECTION
BIf battery charger connects with non battery load,it will go into protection state.
FAULTY BATTERY
Bulk charging has timed out and stopped after 24 hours. Battery is faulty and
may need to be replaced.
OVER VOLTAGE PROTECTION
The 12V charger will automatically protection if the voltage is higher than 17.5V.
The 24V charger will automatically protection if the voltage is higher than 35V.
OVER TEMPERATURE PROTECTION
O
Internal temperature is above 65 C +/-5 C
COOLING FAN
The charger is fitted with a thermostatically controlled fan to cool onboard
electronics and maintain charging performance. The cooling fan will engage
automatically when there is a high load on the battery or there is sufficient heat
build up.
O
4. PROTECTIVE FEATURES